LogoLogo
Contact Uscybus.io
Connectware 1.10.0
Connectware 1.10.0
  • Getting Started
    • Introduction
    • Installing Connectware
      • System Requirements
      • Acquiring your License Key
      • Installing Connectware on Docker
      • Installing Connectware on Kubernetes
    • Connectware Admin UI
    • Basic Components of Connectware
    • Connecting your First Machine
      • Your First Service Commissioning File
  • Documentation
    • Services
      • Service Overview
      • Service Resources View
        • Service Links View
        • Servers View
        • Containers View
        • Volumes View
        • Connections View
        • Endpoints View
        • Mappings View
      • Service Details View
      • Service Commissioning Files
        • Structure of Service Commissioning Files
          • Version
          • Description
          • Metadata
          • Parameters
          • Definitions
          • Resources
            • Cybus::Connection
            • Cybus::Endpoint
            • Cybus:Mapping
            • Cybus::Container
              • Docker problem with network changes
            • Cybus::Link
            • Cybus::IngressRoute
            • Cybus::User
            • Cybus::Role
            • Cybus::Volume
            • Cybus::File
            • Cybus::Server
            • Cybus::Node
      • Setting Up and Configuring Services
        • Installing Services
        • Enabling Services
        • Updating Services
        • Disabling Services
        • Deleting Services
      • FlowSync
        • Example 1 - Node with Transaction Mode (HTTP)
        • Example 2 - Node Responds (HTTP)
        • Example 3 - Node with Error (HTTP)
        • Example 4 - Node with Timeout Error Code and Error Message (HTTP)
        • Example 5 - Full Transactional Data Flow (HTTP)
        • Example 6 - Full Transactional Data Flow (OPC UA)
      • ServiceID
      • Inter-Service Referencing
      • Deviation
      • Service Logs
        • Logs of Individual Services
        • Logs of All Services
      • Rule Engine
        • Data Processing Rules
        • Rule Sandbox
      • Shared Subscriptions
        • Setting Up Shared Subscriptions
    • User Management
      • Users and Roles View
      • Users
      • Roles
      • Permissions
      • Password Policy Rules
      • Default Admin User
      • MQTT Users
      • Adding a MQTT Publish Prefix for Users
      • Multi-Factor Authentication
      • Single Sign-On (SS0)
        • Single Sign-On with Microsoft Entra ID
        • Single Sign-On with LDAP
      • Long lived JSON Web Tokens
      • Access Permissions for Admin-UI
        • UI Access
        • Minimum Access Role Pages
    • Client Registry
      • Implicit Flow
      • Explicit Flow
      • Granting Access
    • Certificates
    • Monitoring
      • Data Explorer
      • Live Data
    • Workbench
      • Flows in Git Repositories
    • System Status
      • Info
      • Metrics
      • Status
      • Retrieving More System Information
      • System Health
    • Backup and Restore
      • Volumes
      • User Database
    • Environment Variables
    • Agents
      • Agents View
      • Installing Agents
        • Installing Agents via Docker
        • Installing Agents via Docker Compose
        • Installing Agents via Kubernetes
        • Using Mutual TLS for Agents
      • Registering Agents in Connectware
      • Using Agents
      • Monitoring Agents
      • Troubleshooting Agents
    • Industry Protocol Details
      • ADS
        • ADS Connection Properties
        • ADS Endpoint Properties
      • BACnet
        • BACnet Connection Properties
        • BACnet Endpoint Properties
      • EtherNet/IP
        • EtherNet/Ip Connection Properties
        • EtherNet/Ip Endpoint Properties
      • FOCAS
        • FOCAS Connection Properties
        • FOCAS Endpoint Properties
      • Generic VRPC
        • Generic VRPC Connection Properties
        • Generic VRPC Endpoint Properties
      • Hottinger Baldwin Messtechnik (HBM)
        • HBM Connection Properties
        • HBM Endpoint Properties
      • Heidenhain DNC
        • Heidenhain DNC Connection Properties
        • Heidenhain DNC Endpoint Properties
      • HTTP/REST
        • HTTP/REST Connection Properties
        • HTTP/REST Endpoint Properties
      • HTTP Server/Node
        • HTTP Server Properties
        • HTTP Node Properties
      • InfluxDB
        • InfluxDB Connection Properties
        • InfluxDB Endpoint Properties
      • Kafka
        • Kafka Connection Properties
        • Kafka Endpoint Properties
      • Modbus/TCP
        • Modbus/TCP Connection Properties
        • Modbus/TCP Endpoint Properties
      • MQTT
        • MQTT Connection Properties
        • MQTT Endpoint Properties
      • MSSQL
        • Mssql Connection Properties
        • Mssql Endpoint Properties
      • OPC DA
        • OPC DA Connection Properties
        • OPC DA Endpoint Properties
      • OPC UA
        • OPC UA Client
          • OPC UA Client Connection Properties
          • OPC UA Client Endpoint Properties
        • OPC UA Server
          • OPC UA Server Properties
          • OPC UA Node Properties
        • OPC UA Object Types
        • OPC UA Server References
          • OPC UA Reference Node
          • OPC UA Object Node
      • Siemens SIMATIC S7
        • Siemens S7 Connection Properties
        • Siemens S7 Endpoint Properties
      • Shdr
        • Shdr Connection Properties
        • Shdr Endpoint Properties
      • SINUMERIK
        • SINUMERIK Connection Properties
        • SINUMERIK Endpoint Properties
      • SOPAS
        • SOPAS Connection Properties
        • SOPAS Endpoint Properties
      • SQL
        • SQL Connection Properties
        • SQL Endpoint Properties
      • Werma WIN Ethernet
        • Werma WIN Ethernet Connection Properties
        • Werma WIN Ethernet Endpoint Properties
      • Systemstate
        • Systemstate Connection Properties
        • Systemstate Endpoint Properties
    • Connectware Licensing
    • API Reference
      • User Management (API)
      • Client Registry (API)
      • Services (API)
      • Resources (API)
      • System Status (API)
      • Industry Protocol Details (API)
    • Changelog
      • General changes from 0.x to 1.0
        • Upgrading from 0.x to 1.0
    • Upgrade Guide
      • Upgrading from 1.x to 1.7.0
      • Upgrading from 1.x to 1.5.0
Powered by GitBook
LogoLogo

Cybus

  • Terms and Condition
  • Imprint
  • Data Privacy

© Copyright 2025, Cybus GmbH

On this page
  • Installing the Service
  • Monitoring Machine Data

Was this helpful?

  1. Getting Started

Connecting your First Machine

In this sample setup, we simulate a machine connecting to Connectware via the OPC UA protocol. The demo instance includes a simulated machine that generates sample data.

PreviousBasic Components of ConnectwareNextYour First Service Commissioning File

Last updated 4 months ago

Was this helpful?

Installing the Service

In this example setup we will install a Connectware service via the sample service commissioning file to make a connection to a machine via the OPC UA protocol.

The sample service commissioning file contains all the configuration that are needed to install the service. Once we have installed the service, the machine connection will be automatically included in your Connectware dashboard.

  1. Download the sample service commissioning file. To learn more about the structure of this service commissioning file, see .

  1. Open your browser and enter the IP address of your host (https://<HOST-IP>).

  2. Enter your Username and Password.

    • The default login credentials are:

      • Username: admin

      • Password: admin

  3. Click Sign in.

  4. On the navigation panel, click Services.

  1. Click Upload Service.

  2. Click Choose File and select the connect-your-first-machine.yaml file.

  3. Click Install to confirm the parameters and start the installation. The service is now installed but not yet enabled.

  4. In the Service Overview list, click your service to open the Service Details view.

  5. To enable the service, click Enable.

  6. In the Authorization Required dialog, click Allow to confirm the configuration changes to Connectware.

Your service is now installed and the data can flow. Lets monitor the incoming machine data in the Data Explorer of Connectware.

Monitoring Machine Data

Data in the form of MQTT messages is organized into topics for easy structuring and interconnection by any publisher or subscriber. The Data Explorer view allows you to monitor the data of your topics.

  1. On the navigation panel, click Data.

  2. In the Available Topics list, select your connection. You can now monitor the incoming machine data.

Your First Service Commissioning File
1KB
connect-your-first-machine.yaml