LogoLogo
Contact Uscybus.io
Connectware 1.7.2
Connectware 1.7.2
  • Getting Started
    • Introduction
    • Installing Connectware
      • System Requirements
      • Acquiring your License Key
      • Installing Connectware on Docker
      • Installing Connectware on Kubernetes
    • Connectware Admin UI
    • Basic Components of Connectware
    • Connecting your First Machine
      • Your First Service Commissioning File
  • Documentation
    • Services
      • Structure of Commissioning Files
        • version
        • description
        • metadata
        • parameters
        • definitions
        • resources
          • Cybus::Connection
          • Cybus::Endpoint
          • Cybus:Mapping
          • Cybus::Container
            • Docker problem with network changes
          • Cybus::Link
          • Cybus::IngressRoute
          • Cybus::User
          • Cybus::Role
          • Cybus::Volume
          • Cybus::File
          • Rules Objects
          • Cybus::Server
          • Cybus::Node
      • ServiceID
      • Inter-Service Referencing
      • Deviation
      • Working with Service Commissioning Files
      • Service Details View
      • Sample Service Commissioning Files
        • Modbus
          • “Bearbeitungszentrum BAZ” - Single File
          • “Bearbeitungszentrum BAZ” - Multiple Files
          • “Bearbeitungszentrum BAZ” - Single File and Custom Topics
          • “Bearbeitungszentrum BAZ” - Agent Mode
        • Machine Condition Monitoring : OPC UA + InfluxDB + Grafana Dashboard
          • “Machine Condition Monitoring Example” - Single File
        • Machine Utilization Example (Multi file service composition) : Modbus TCP + InfluxDB + Grafana + MSS
          • “Machine Utilization Example” - Machine Connectivity
          • “Machine Utilization Example” - Dashboards with role based access permission
          • “Machine Utilization Example” - Push data to MSSQL Database
      • API Definition
    • Resources
      • Containers
      • Volumes
      • Connections
      • Endpoints
      • Mappings
      • Servers
      • Nodes
      • API Definition
    • User Management
      • Users and Roles View
      • Users
      • Roles
      • Permissions
      • Password Policy Rules
      • Default Admin User
      • MQTT Users
      • Adding a MQTT Publish Prefix for Users
      • Multi-Factor Authentication
      • Long lived JSON Web Tokens
      • Access Permissions for Admin-UI
        • UI Access
        • Minimum Access Role Pages
      • API Definition
    • Client Registry
      • Implicit Flow
      • Explicit Flow
      • Granting Access
      • API Definition
    • Certificates
    • Explorer
    • Workbench
      • Flows in Git Repositories
    • System Status
      • Info
      • Metrics
      • Status
      • Retrieving More System Information
      • System Health
      • API Definition
    • Backup and Restore
      • Volumes
      • User Database
    • Configuration
      • Environment Variables
      • LDAP Configuration
      • MFA Configuration
    • Agents
      • Installation
      • Registration
      • Usage
      • Monitoring
    • Industry Protocol Details
      • ADS
        • AdsConnection
        • AdsEndpoint
      • BACnet
        • BacnetConnection
        • BacnetEndpoint
      • EtherNet/IP
        • EthernetIpConnection
        • EthernetIpEndpoint
      • Focas
        • FocasConnection
        • FocasEndpoint
      • Generic VRPC
        • GenericVrpcConnection
        • GenericVrpcEndpoint
      • Hottinger Baldwin Messtechnik (HBM)
        • HbmdaqConnection
        • HbmdaqEndpoint
      • Heidenhain DNC
        • HeidenhainConnection
        • HeidenhainEndpoint
      • HTTP/REST
        • HttpConnection
        • HttpEndpoint
      • HTTP Server
        • HttpServer
        • HttpNode
      • InfluxDB
        • InfluxdbConnection
        • InfluxdbEndpoint
      • Kafka
        • KafkaConnection
        • KafkaEndpoint
      • Modbus/TCP
        • ModbusConnection
        • ModbusEndpoint
      • MQTT
        • MqttConnection
        • MqttEndpoint
      • MSSQL
        • MssqlConnection
        • MssqlEndpoint
      • OPC DA
        • OpcdaConnection
        • OpcdaEndpoint
      • OPC UA
        • OPC UA Client
          • OpcuaConnection
          • OpcuaEndpoint
        • OPC UA Server
          • OpcuaServer
          • OpcuaNode
        • OPC UA Object Types
        • OPC UA Server References
          • OpcuaReferenceNode
          • OpcuaObjectNode
      • Profinet
        • ProfinetConnection
        • ProfinetEndpoint
      • Siemens SIMATIC S7
        • S7Connection
        • S7Endpoint
      • Shdr
        • ShdrConnection
        • ShdrEndpoint
      • Sinumerik
        • SinumerikConnection
        • SinumerikEndpoint
      • Sopas
        • SopasConnection
        • SopasEndpoint
      • SQL
        • SqlConnection
        • SqlEndpoint
      • Werma WIN Ethernet
        • WermaConnection
        • WermaEndpoint
      • Systemstate
        • SystemstateConnection
        • SystemstateEndpoint
      • API Definition
    • Connectware Licensing
    • Changelog and Upgrade Guide
      • Upgrading from 1.x to 1.7.0
      • Upgrading from 1.x to 1.5.0
      • General changes from 0.x to 1.0
        • Upgrading from 0.x to 1.0
Powered by GitBook
LogoLogo

Cybus

  • Terms and Condition
  • Imprint
  • Data Privacy

© Copyright 2025, Cybus GmbH

On this page
  • host (string, required)
  • port (integer, required)
  • resourcePath (string)
  • username (string)
  • password (string)
  • timeout (integer)
  • options (object)

Was this helpful?

  1. Documentation
  2. Industry Protocol Details
  3. Sinumerik

SinumerikConnection

host (string, required)

Hostname or IP of the Sinumerik device

Example: "192.168.2.60"

port (integer, required)

Port of the Sinumerik device

Default: 4840

Example: 4840

resourcePath (string)

Path of the Sinumerik server

Default: ""

Example: ""

username (string)

Username for Sinumerik server

Example: "user"

password (string)

Password for Sinumerik server

Example: "user"

timeout (integer)

Timeout, in milliseconds

Default: 1000

Examples: 1000, 2000

options (object)

Properties of the options object:

defaultSecureTokenLifetime (integer)

Lifetime of the secure token. Specified in milliseconds.

Default: 3600000

requestedSessionTimeout (integer)

OPC UA sessions may survive TCP connection breaks and are only deleted if no message from a client is received within the timeout period. Specified in milliseconds.

Default: 3600000

endpointMustExist (boolean)

Specifies if the connection is strictly meant for the given endpoint. If false and the endpoint doesn’t exist, a reasonable default endpoint is automatically chosen.

Default: false

messageSecurityMode (string, enum)

This element must be one of the following enum values:

  • None

  • Sign

  • SignAndEncrypt

Default: "None"

securityPolicy (string, enum)

This element must be one of the following enum values:

  • Aes128_Sha256_RsaOaep

  • Basic128

  • Basic128Rsa15

  • Basic192

  • Basic192Rsa15

  • Basic256

  • Basic256Rsa15

  • Basic256Sha256

  • None

  • PubSub_Aes128_CTR

  • PubSub_Aes256_CTR

Default: "None"

watchInterval (integer)

For observing connection breaks, a connection watchdog runs regularly. Short intervals guarantee short notice on break but lead to higher load. Specified in milliseconds

Default: 30000

connectionStrategy (object)

If a connection attempt failes, retries will be performed with growing delays in between. The following parameter control how these delays behave.

Properties of the connectionStrategy object:

maxRetry (integer)

Maximum number of connection retries in case of failure.

Default: 1000000000

initialDelay (integer)

Delay of the first retry. Consecutive retries will randomly take longer delays.

Default: 1000

maxDelay (integer)

Maximum delay of a retry.

Default: 60000

randomisationFactor (number)

This parameter controls added randomisation to the retry attempts. Must be a number between 0 and 1. If set to 0, retries will be performed with exponentially growing delay until maxDelay. If set to 1, a maximum noise will be added to the retry delays.

Default: 0

Additional restrictions:

  • Maximum: 1

PreviousSinumerikNextSinumerikEndpoint

Last updated 8 months ago

Was this helpful?