LogoLogo
Contact Uscybus.io
Connectware 1.8.0
Connectware 1.8.0
  • Getting Started
    • Introduction
    • Installing Connectware
      • System Requirements
      • Acquiring your License Key
      • Installing Connectware on Docker
      • Installing Connectware on Kubernetes
    • Connectware Admin UI
    • Basic Components of Connectware
    • Connecting your First Machine
      • Your First Service Commissioning File
  • Documentation
    • Services
      • Service Commissioning Files
        • Structure of Service Commissioning Files
          • description
          • metadata
          • parameters
          • definitions
          • resources
            • Cybus::Connection
            • Cybus::Endpoint
            • Cybus:Mapping
            • Cybus::Container
              • Docker problem with network changes
            • Cybus::Link
            • Cybus::IngressRoute
            • Cybus::User
            • Cybus::Role
            • Cybus::Volume
            • Cybus::File
            • Cybus::Server
            • Cybus::Node
        • Sample Service Commissioning Files
          • Modbus
            • “Bearbeitungszentrum BAZ” - Single File
            • “Bearbeitungszentrum BAZ” - Multiple Files
            • “Bearbeitungszentrum BAZ” - Single File and Custom Topics
            • “Bearbeitungszentrum BAZ” - Agent Mode
          • Machine Condition Monitoring : OPC UA + InfluxDB + Grafana Dashboard
            • “Machine Condition Monitoring Example” - Single File
          • Machine Utilization Example (Multi file service composition) : Modbus TCP + InfluxDB + Grafana + MSS
            • “Machine Utilization Example” - Machine Connectivity
            • “Machine Utilization Example” - Dashboards with role based access permission
            • “Machine Utilization Example” - Push data to MSSQL Database
      • Services View
      • Setting Up and Configuring Services
        • Installing Services
        • Enabling Services
        • Updating Services
        • Disabling Services
        • Deleting Services
      • Service Details View
      • ServiceID
      • Inter-Service Referencing
      • Deviation
      • Service Logs
        • Logs of Individual Services
        • Logs of All Services
      • Rule Engine
        • Data Processing Rules
        • Rule Sandbox
      • API Definition
    • Resources
      • Servers
      • Containers
      • Volumes
      • Connections
      • Endpoints
      • Mappings
      • Nodes
      • API Definition
    • User Management
      • Users and Roles View
      • Users
      • Roles
      • Permissions
      • Password Policy Rules
      • Default Admin User
      • MQTT Users
      • Adding a MQTT Publish Prefix for Users
      • Multi-Factor Authentication
      • Long lived JSON Web Tokens
      • Access Permissions for Admin-UI
        • UI Access
        • Minimum Access Role Pages
      • API Definition
    • Client Registry
      • Implicit Flow
      • Explicit Flow
      • Granting Access
      • API Definition
    • Certificates
    • Monitoring
      • Data Explorer
      • Live Data
    • Workbench
      • Flows in Git Repositories
    • System Status
      • Info
      • Metrics
      • Status
      • Retrieving More System Information
      • System Health
      • API Definition
    • Backup and Restore
      • Volumes
      • User Database
    • Configuration
      • Environment Variables
      • LDAP Configuration
      • MFA Configuration
    • Agents
      • Agents View
      • Installing Agents
        • Installing Agents via Docker
        • Installing Agents via Docker Compose
        • Installing Agents via Kubernetes
        • Using Mutual TLS for Agents
      • Registering Agents in Connectware
      • Using Agents
      • Monitoring Agents
      • Troubleshooting Agents
    • Industry Protocol Details
      • ADS
        • AdsConnection
        • AdsEndpoint
      • BACnet
        • BacnetConnection
        • BacnetEndpoint
      • EtherNet/IP
        • EthernetIpConnection
        • EthernetIpEndpoint
      • Focas
        • FocasConnection
        • FocasEndpoint
      • Generic VRPC
        • GenericVrpcConnection
        • GenericVrpcEndpoint
      • Hottinger Baldwin Messtechnik (HBM)
        • HbmdaqConnection
        • HbmdaqEndpoint
      • Heidenhain DNC
        • HeidenhainConnection
        • HeidenhainEndpoint
      • HTTP/REST
        • HttpConnection
        • HttpEndpoint
      • HTTP Server
        • HttpServer
        • HttpNode
      • InfluxDB
        • InfluxdbConnection
        • InfluxdbEndpoint
      • Kafka
        • KafkaConnection
        • KafkaEndpoint
      • Modbus/TCP
        • ModbusConnection
        • ModbusEndpoint
      • MQTT
        • MqttConnection
        • MqttEndpoint
      • MSSQL
        • MssqlConnection
        • MssqlEndpoint
      • OPC DA
        • OpcdaConnection
        • OpcdaEndpoint
      • OPC UA
        • OPC UA Client
          • OpcuaConnection
          • OpcuaEndpoint
        • OPC UA Server
          • OpcuaServer
          • OpcuaNode
        • OPC UA Object Types
        • OPC UA Server References
          • OpcuaReferenceNode
          • OpcuaObjectNode
      • Siemens SIMATIC S7
        • S7Connection
        • S7Endpoint
      • Shdr
        • ShdrConnection
        • ShdrEndpoint
      • Sinumerik
        • SinumerikConnection
        • SinumerikEndpoint
      • Sopas
        • SopasConnection
        • SopasEndpoint
      • SQL
        • SqlConnection
        • SqlEndpoint
      • Werma WIN Ethernet
        • WermaConnection
        • WermaEndpoint
      • Systemstate
        • SystemstateConnection
        • SystemstateEndpoint
      • API Definition
    • Connectware Licensing
    • Changelog
      • General changes from 0.x to 1.0
        • Upgrading from 0.x to 1.0
    • Upgrade Guide
      • Upgrading from 1.x to 1.7.0
      • Upgrading from 1.x to 1.5.0
Powered by GitBook
LogoLogo

Cybus

  • Terms and Condition
  • Imprint
  • Data Privacy

© Copyright 2025, Cybus GmbH

On this page

Was this helpful?

  1. Documentation
  2. Agents

Registering Agents in Connectware

PreviousUsing Mutual TLS for AgentsNextUsing Agents

Last updated 6 months ago

Was this helpful?

Registering agents in Connectware enables them to connect to Connectware.

You must register agents in any of the following cases:

  • The agent is being started for the first time.

  • The persisted credentials have been deleted.

  • The agent is unable to log into Connectware with its cached credentials.

In all other cases, registering agents is not required and the agent will run using the stored credentials from the volume it is mounted on.

If multiple agents are to run on the same computer, each agent must use its own volume mount, otherwise the agents will overwrite each other's credentials.

During the initial deployment, the registration process is as follows:

  1. Start the agent container. The container's console log should display messages like this:

{"level":30,"time":1590665714502,"msg":"Starting in distributed (edge) mode","pid":6,"hostname":"someHost","v":1}
{"level":30,"time":1590665714568,"msg":"Asking for Connectware registration at 1.2.3.4 with newly generated credentials...","pid":6,"hostname":"someHost","v":1}
{"level":30,"time":1590665714568,"msg":"The registration process must be finished using the web-interface.","pid":6,"hostname":"someHost","v":1}
{"level":30,"time":1590665714568,"msg":"Navigate to \"User Management -> Client Registry\", click unlock and authorize this client.","pid":6,"hostname":"someHost","v":1}
{"level":30,"time":1590665714568,"msg":"Username: cybus-sample-agent, pairing ID (should match in UI): a82123","pid":6,"hostname":"someHost","v":1}

If you encounter a 409 Conflict error, it means that there is a registration conflict that must be resolved. For more information, see .

  1. To complete the agent registration, log into Connectware and authorize the client through the Client Registry view. For more information, see .

In addition to the agent name, you can also compare the Pairing ID to verify that you are granting access to the correct agent instance.

Client Registry
User Registration Conflict (409 Conflict)