LogoLogo
Contact Uscybus.io
Connectware 1.8.0
Connectware 1.8.0
  • Getting Started
    • Introduction
    • Installing Connectware
      • System Requirements
      • Acquiring your License Key
      • Installing Connectware on Docker
      • Installing Connectware on Kubernetes
    • Connectware Admin UI
    • Basic Components of Connectware
    • Connecting your First Machine
      • Your First Service Commissioning File
  • Documentation
    • Services
      • Service Commissioning Files
        • Structure of Service Commissioning Files
          • description
          • metadata
          • parameters
          • definitions
          • resources
            • Cybus::Connection
            • Cybus::Endpoint
            • Cybus:Mapping
            • Cybus::Container
              • Docker problem with network changes
            • Cybus::Link
            • Cybus::IngressRoute
            • Cybus::User
            • Cybus::Role
            • Cybus::Volume
            • Cybus::File
            • Cybus::Server
            • Cybus::Node
        • Sample Service Commissioning Files
          • Modbus
            • “Bearbeitungszentrum BAZ” - Single File
            • “Bearbeitungszentrum BAZ” - Multiple Files
            • “Bearbeitungszentrum BAZ” - Single File and Custom Topics
            • “Bearbeitungszentrum BAZ” - Agent Mode
          • Machine Condition Monitoring : OPC UA + InfluxDB + Grafana Dashboard
            • “Machine Condition Monitoring Example” - Single File
          • Machine Utilization Example (Multi file service composition) : Modbus TCP + InfluxDB + Grafana + MSS
            • “Machine Utilization Example” - Machine Connectivity
            • “Machine Utilization Example” - Dashboards with role based access permission
            • “Machine Utilization Example” - Push data to MSSQL Database
      • Services View
      • Setting Up and Configuring Services
        • Installing Services
        • Enabling Services
        • Updating Services
        • Disabling Services
        • Deleting Services
      • Service Details View
      • ServiceID
      • Inter-Service Referencing
      • Deviation
      • Service Logs
        • Logs of Individual Services
        • Logs of All Services
      • Rule Engine
        • Data Processing Rules
        • Rule Sandbox
      • API Definition
    • Resources
      • Servers
      • Containers
      • Volumes
      • Connections
      • Endpoints
      • Mappings
      • Nodes
      • API Definition
    • User Management
      • Users and Roles View
      • Users
      • Roles
      • Permissions
      • Password Policy Rules
      • Default Admin User
      • MQTT Users
      • Adding a MQTT Publish Prefix for Users
      • Multi-Factor Authentication
      • Long lived JSON Web Tokens
      • Access Permissions for Admin-UI
        • UI Access
        • Minimum Access Role Pages
      • API Definition
    • Client Registry
      • Implicit Flow
      • Explicit Flow
      • Granting Access
      • API Definition
    • Certificates
    • Monitoring
      • Data Explorer
      • Live Data
    • Workbench
      • Flows in Git Repositories
    • System Status
      • Info
      • Metrics
      • Status
      • Retrieving More System Information
      • System Health
      • API Definition
    • Backup and Restore
      • Volumes
      • User Database
    • Configuration
      • Environment Variables
      • LDAP Configuration
      • MFA Configuration
    • Agents
      • Agents View
      • Installing Agents
        • Installing Agents via Docker
        • Installing Agents via Docker Compose
        • Installing Agents via Kubernetes
        • Using Mutual TLS for Agents
      • Registering Agents in Connectware
      • Using Agents
      • Monitoring Agents
      • Troubleshooting Agents
    • Industry Protocol Details
      • ADS
        • AdsConnection
        • AdsEndpoint
      • BACnet
        • BacnetConnection
        • BacnetEndpoint
      • EtherNet/IP
        • EthernetIpConnection
        • EthernetIpEndpoint
      • Focas
        • FocasConnection
        • FocasEndpoint
      • Generic VRPC
        • GenericVrpcConnection
        • GenericVrpcEndpoint
      • Hottinger Baldwin Messtechnik (HBM)
        • HbmdaqConnection
        • HbmdaqEndpoint
      • Heidenhain DNC
        • HeidenhainConnection
        • HeidenhainEndpoint
      • HTTP/REST
        • HttpConnection
        • HttpEndpoint
      • HTTP Server
        • HttpServer
        • HttpNode
      • InfluxDB
        • InfluxdbConnection
        • InfluxdbEndpoint
      • Kafka
        • KafkaConnection
        • KafkaEndpoint
      • Modbus/TCP
        • ModbusConnection
        • ModbusEndpoint
      • MQTT
        • MqttConnection
        • MqttEndpoint
      • MSSQL
        • MssqlConnection
        • MssqlEndpoint
      • OPC DA
        • OpcdaConnection
        • OpcdaEndpoint
      • OPC UA
        • OPC UA Client
          • OpcuaConnection
          • OpcuaEndpoint
        • OPC UA Server
          • OpcuaServer
          • OpcuaNode
        • OPC UA Object Types
        • OPC UA Server References
          • OpcuaReferenceNode
          • OpcuaObjectNode
      • Siemens SIMATIC S7
        • S7Connection
        • S7Endpoint
      • Shdr
        • ShdrConnection
        • ShdrEndpoint
      • Sinumerik
        • SinumerikConnection
        • SinumerikEndpoint
      • Sopas
        • SopasConnection
        • SopasEndpoint
      • SQL
        • SqlConnection
        • SqlEndpoint
      • Werma WIN Ethernet
        • WermaConnection
        • WermaEndpoint
      • Systemstate
        • SystemstateConnection
        • SystemstateEndpoint
      • API Definition
    • Connectware Licensing
    • Changelog
      • General changes from 0.x to 1.0
        • Upgrading from 0.x to 1.0
    • Upgrade Guide
      • Upgrading from 1.x to 1.7.0
      • Upgrading from 1.x to 1.5.0
Powered by GitBook
LogoLogo

Cybus

  • Terms and Condition
  • Imprint
  • Data Privacy

© Copyright 2025, Cybus GmbH

On this page
  • symbolName (string, required)
  • interval (integer)
  • onChange (boolean)
  • dataType (string, enum)
  • readSize (integer)

Was this helpful?

  1. Documentation
  2. Industry Protocol Details
  3. ADS

AdsEndpoint

symbolName (string, required)

The name of the variable to read/write/subscribe

Example: "Main.byByte[4]"

interval (integer)

Only for subscribe: The time interval between subsequent reads, in milliseconds. The value is received cyclically from the PLC at this interval. The smallest possible theoretical value is the cycle time of the PLC. If the interval is set to zero, the value is read at every PLC cycle. However, when setting the time interval to a small value, the MQTT broker of the Connectware might not be able to handle the resulting high data rate and data loss might occur, hence small time intervals must be handled with care. (The maximum value of 429 seconds is caused by the data type limit of this field within the ADS protocol.)

Default: 1000

Additional restrictions:

  • Maximum: 429496

onChange (boolean)

Only for subscribe: How subscriptions should report the variable values. If true, a value is sent only when it changed. If false, the value is sent on each time interval.

Default: false

dataType (string, enum)

Convert the ADS value to this specified type. Types are available in Big Endian (BE) variants or Little Endian (LE).

This element must be one of the following enum values:

  • raw

  • string

  • boolean

  • doubleBE

  • doubleLE

  • floatBE

  • floatLE

  • int8

  • int16BE

  • int16LE

  • int32BE

  • int32LE

  • bigInt64BE

  • bigInt64LE

  • uint16BE

  • uint16LE

  • uint32BE

  • uint32LE

  • bigUInt64BE

  • bigUInt64LE

Default: "raw"

Examples: "floatLE", "string"

readSize (integer)

Only needed for read variables of type string or raw: The number of bytes to read.

Default: 1

Additional restrictions:

  • Minimum: 1

PreviousAdsConnectionNextBACnet

Last updated 6 months ago

Was this helpful?