FOCAS Endpoint Properties

method (string, enum, required)

The method to run on the device

This element must be one of the following enum values:

  • cnc_sysinfo

  • cnc_statinfo2

  • cnc_rdprgnum

  • cnc_exeprgname

  • cnc_rdopnlsgnl

  • pmc_rdpmcrng

  • cnc_rdspeed

  • cnc_rdspload

  • cnc_rdgcode

  • program_download

Example: "cnc_sysinfo"

interval (integer)

The interval between reads (only for the subscribe operation)

Default: 1000

Additional restrictions:

  • Minimum: 500

cronExpression (string)

The Cron expression used to poll the endpoint. (For examples, see: https://github.com/node-cron/node-cron)

Examples: "1,2,4,5 * * * *", "1-5 * * * *", "*/2 * * * *", "* * * January,September Sunday"

slctData (integer)

Specify the data select flag (only applies for the cnc_rdopnlsgnl method)

Default: 32767

Additional restrictions:

  • Maximum: 32767

addressType (integer)

Specify the identification code corresponding to the kind of the PMC address (only applies for the pmc_rdpmcrng method)

Default: 0

Additional restrictions:

  • Maximum: 13

dataType (integer, enum)

Specify the type of the PMC data or CNC feed rate/spindle speed (only applies for the methods pmc_rdpmcrng and cnc_rdspeed), which can be byte (0), word (1), long (2), float32 (4) or float64 (5). float32 and float64 apply for 30i-B Series/0i-F/PMi-A only. For method cnc_rdspeed valid values are 0 (feed rate), 1 (spindle speed), -1 (all)

This element must be one of the following enum values:

  • -1

  • 0

  • 1

  • 2

  • 4

  • 5

Default: 0

spindleNumber (integer)

Specify spindle number to read. from 1 up to 8 for Series 30i, 0i-D/F. 1 up to 4 for Series 15/15i, 16i/18i/21i, 16i/18i/21i, 0i-A/B/C. And only number 1 for Power Mate i-D

Default: 1

Additional restrictions:

  • Minimum: 1

  • Maximum: 8

type (integer)

Specify the group of G code. Only applies for method cnc_rdgcode. Series 15i: goes from 0 to 18,24,25,27/-1/100 to 103/-2. For Series 30i, 0i-D/F, PMi-A: goes from 0 to 36/-1/100 to 103/-2

Default: -1

Additional restrictions:

  • Minimum: -2

  • Maximum: 103

block (integer)

Specify the block to be read. 0 -> previus block, 1 -> active block, 2 -> next block. Only applies for method cnc_rdgcode

Default: 1

Additional restrictions:

  • Maximum: 2

numGcd (integer)

number of G code data to be read. Only applies for method cnc_rdgcode

Default: 1

Additional restrictions:

  • Minimum: 1

addressStart (integer)

Specify the start PMC address number (only applies for the pmc_rdpmcrng method)

Default: 0

addressEnd (integer)

Specify the end PMC address number (only applies for the pmc_rdpmcrng method)

Default: 0

dataLength (integer)

Specify the data block length (only applies for the pmc_rdpmcrng method)

Default: 8

Additional restrictions:

  • Minimum: 8