Open Protocol
Connect tightening controllers over Open Protocol, subscribe to MID groups, send requests and commands, and pin revisions.
The Open Protocol connector connects Connectware to tightening controllers from Atlas Copco, Bosch Rexroth, and Desoutter. It publishes tightening results, alarms, and curves as MQTT messages and sends commands to the controller, such as selecting a parameter set.
How the Open Protocol Connector Works
Open Protocol exchanges messages over TCP. Every message type has a four-digit message ID (MID), such as MID 0061 for the last tightening result. A connection is one TCP session to one controller. An endpoint addresses one MID group, a keyword such as lastTightening for the MIDs of one function, or one MID by its number.
subscribe
The controller pushes data, for example after every tightening.
The connector publishes on the endpoint topic.
read
Connectware sends a request MID and receives the reply MID.
Publish the request on <topic>/req. The reply arrives on <topic>/res.
write
Connectware sends a command MID.
Publish the command on <topic>/set. The result arrives on <topic>/res.
The endpoint topic is services/<serviceId>/<topic>, where <topic> is the endpoint's topic property.
Connecting to a Controller
Set protocol to Openprotocol, the controller's address in host, and the controller in device. The port defaults to 4545.
device.vendor:AtlasCopco,Bosch, orDesoutter, in any letter case. Another value is treated asAtlasCopco, and the connector logs a warning.device.model: a free-form model name, used for diagnostics only.
openProtocolConnection:
type: Cybus::Connection
properties:
protocol: Openprotocol
connection:
host: 192.168.1.100
port: 4545
device:
vendor: AtlasCopco
model: PowerFocus6000Header Style
headerStyle sets how the connector writes the unused optional fields of the message header: digits writes explicit digits, spaces leaves them blank. The default is spaces for Desoutter and digits for every other vendor.
Keep-Alive and Timeouts
The connector sends a keep-alive message (MID 9999) every keepAlive milliseconds, 10,000 by default. Keep the interval below the controller's keep-alive timeout, which the Open Protocol specification sets at 15 seconds.
The connector waits timeOut milliseconds (default 3000) for an answer and repeats the wait retryTimes times (default 3). If no answer arrives within timeOut * (retryTimes + 1), 12 seconds with the defaults, the connector gives up on the message, closes the connection, and reconnects.
To use link-level acknowledgement (MID 9997 and MID 9998) instead of application-level acknowledgement, set linkLayerActivate: true.
Generic Mode
With genericMode: true, the connector sends requests with the generic request message (MID 0006) and subscribes with the generic subscription messages (MID 0008 and MID 0009) instead of the dedicated MID of each group. Use it for controllers that implement only the generic messages.
Reconnecting
When the connection is lost, Connectware reconnects according to connectionStrategy. Subscriptions are restored once the connection is back.
A watchdog drops a connection that stays open while the controller stops sending. If the connector receives nothing, keep-alive replies included, for watchdog.inactivityThreshold milliseconds (default 120,000), it drops the connection and reconnects. To turn the watchdog off, set watchdog.enabled to false.
Addressing a MID
An endpoint sets either midGroup or mid. An endpoint that sets neither or both goes into an error state, and the rest of the service keeps running.
MID Groups
midGroup names a MID group from the MID Group Reference. The same keyword can resolve to different MIDs per operation. For example, toolTagID as a subscription receives MID 0262, and as a read sends MID 0260.
MID Numbers
mid addresses a MID that no MID group covers, such as a vendor-specific MID 1000 or higher:
For
subscribe, it is the data MID the controller pushes.For
read, it is the request MID. If the specification does not define the reply MID, set it inreplyMid.For
write, it is the command MID.
Function Numbers and Trace Types
The following subscriptions take a property that selects what they receive:
relayFunctionanddigitalInputFunction: set the function number from the controller's tables infunctionNumber. Without it, the endpoint receives the data of every function.traceData: set the curve intraceType:angle,torque(default),current,gradient,stroke, orforce. Use one endpoint per curve.
Sending Requests and Commands
The message you publish on <topic>/req or <topic>/set becomes the data field of the MID:
A string or number is sent as published.
002arrives as the three characters002.An empty message or
{}sends the MID without a data field.A JSON object works for the MID groups in the following table. If a field is missing or a number is too wide, the connector sends nothing and publishes an error on
<topic>/res.
selectPset
0018
{"parameterSetID": 2}
002
setPsetBatchSize
0019
{"parameterSetID": 2, "batchSize": 4}
00204
resetPsetBatchCounter
0020
{"parameterSetID": 2}
002
selectJob
0038
{"jobID": 1}
01, or 0001 when MID 0038 is pinned to revision 2
jobRestart
0039
{"jobID": 1}
01, or 0001 when MID 0039 is pinned to revision 2
vinDownload
0050
{"numberVIN": "VIN12345678"}
The VIN, padded with spaces to 25 characters
setTime
0082
{"time": "2025-06-01:12:00:00"}
2025-06-01:12:00:00
oldTighteningResultUpload (read)
0064
{"tighteningID": 123456}
0000123456
The following MID groups take no data field. The connector sends them without one and ignores any payload you publish.
psetID
0010
read
jobIdUpload
0030
read
toolDataUpload, below revision 6
0040
read
readTimeUpload
0080
read
toolTagID
0260
read
autoDisableSettings
0410
read
modeIdUpload
2600
read
keepAlive
9999
read
communicationStop
0003
write
parameterUserSetDownload
0025
write
disableTool
0042
write
enableTool
0043
write
disconnectTool
0044
write
flashGreenLightOnTool
0113
write
abortJob
0127
write
jobBatchIncrement
0128
write
setJobLineControlStart
0131
write
setJobLineAlert1
0132
write
setJobLineAlert2
0133
write
bypassIdentifier
0155
write
resetLatestIdentifier
0156
write
resetAllIdentifiers
0157
write
controllerReboot
0270
write
motorTuning
0504
write
${SERVICE_ID}: the ID of the service that contains the endpoints.
Correlating Requests and Results
To match a result to its request, publish {"id": …, "value": …}, with the data field in value and an id of any JSON type. The result arrives as {"id": …, "result": …}. An object with only id sends the MID without a data field.
If the endpoint has rules, they receive the whole {"id": …, "result": …} object. To keep the correlation, copy id into the rule output.
Published Messages
The connector publishes each MID as the controller sent it:
midandrevisionare the MID and revision the message arrived with. A controller can answer at a lower revision than requested, and the payload follows that revision.The other fields come from the message header. A blank header field is
0.payloadholds the data field. The message carries no Connectware time stamp, so use the controller's, such aspayload.timeStamp.
With rawData: true on the connection, every message also carries _raw, the data field as received, as {"type": "Buffer", "data": [...]}.
Decoded and Raw Payloads
The connector decodes the following MIDs into JSON objects at the listed revisions:
0015
psetSelected
1–2
0035
jobInfo
1–5
0052
vin
1–2
0061
lastTightening
1–7, 998, 999
0065
oldTighteningResultUpload
1–7
0071
alarm
1–2
0074
alarmAcknowledged
1
0076
alarmStatus
1–2
0081
readTimeUpload
1
0106
lastPowerMACSTighteningResultStationData
1–3
0900
traceData
1
0901
plotData
1
Every other MID, and a decoded MID at another revision or with an unexpected layout, is published as a string, untrimmed. To receive a MID as bytes instead, list it in the connection's disableMidParsing property, for example "61,900".
Payload Fields
Text fields are trimmed, except
numberVIN, which keeps all 25 characters.Controller time stamps are strings in the format
YYYY-MM-DD:HH:MM:SS.In
lastTightening, coded fields are texts, and a twin field with an underscore prefix holds the code. For example,torqueStatusreadsLOW,OK, orHIGH, and_torqueStatusholds the number. Bit fields are lists with one entry per bit, least significant bit first, holding the text of a set bit ornull.A loosening arrives on
lastTighteningwithresultTypeset toLoosening.
Torque values are scaled differently per MID:
0061 (lastTightening)
Divided by 100. Angles are whole degrees.
torque: 8.34 is 8.34 Nm
0065 (oldTighteningResultUpload)
Not scaled. Statuses are numbers without texts.
torque: 1234 is 12.34 Nm
0015 (psetSelected, revision 2)
Not scaled.
1000 is 10.00 Nm
0013 (psetData, string)
Scaled by 100 in the string.
000700 is 7.00 Nm
psetData is a string of numbered fields, each a two-digit field number followed by a fixed-width value. At revisions 3 and 4, an eight-character file version comes first. Parse it field by field, not by character position.
Trace and Plot Data
traceData publishes one curve per tightening. Each sample in sampleTrace has a value, already multiplied by the controller's coefficient, and a timeStamp as an ISO 8601 string. The connector reads the controller's time as its own local time, which is UTC by default. For example, 2026-08-17:15:32:13 becomes 2026-08-17T15:32:13.000Z.
plotData publishes the limit lines around the curve and needs its own endpoint. In fieldPID, parameter IDs 02002, 02003, 02012, and 02013 are lines of four 8-character fields in the order y1, x1, y2, x2. Parameter IDs 05150 and 05151 hold the start and stop of each tightening step.
Both carry the tightening in payload.resultID. The curve can arrive before its limit lines, so to combine them, keep the curve until the limit lines with the same resultID arrive.
Results and Errors
Every read and write publishes its outcome on <topic>/res:
A successful
readpublishes the reply MID.An accepted
writepublishes the controller's acknowledgement, MID 0005, with the command MID inpayload.midNumber.A failed
readorwritepublishes an error object.
code is the error code from the controller's error message (MID 0004), as defined in the Open Protocol specification. It is missing when the controller did not reject the message, for example on a timeout, a lost connection, or an invalid payload. The error object is published regardless of publishError.
A request that arrives while the connection is down is not sent, and <topic>/res receives an empty message.
Revisions
The fields of a payload depend on the revision of its MID. The connector starts the following MIDs at a higher revision, and every other MID at revision 1:
0014
psetSelected subscription
2
0051
vin subscription
2
0060
lastTightening subscription
7
0064
oldTighteningResultUpload request
7
0070
alarm subscription
2
If the controller refuses a subscription or request with error 97 or 74 (revision unsupported), the connector retries one revision lower, down to revision 1. Commands do not step down.
Pinning Revisions
To send a MID at exactly one revision, pin it with fixedRevisions on the connection, for all endpoints, or with revision on one endpoint. A fixedRevisions entry reads "{60,3}", "60,3", or '{"MID": 60, "Revision": 3}'.
A pin names the MID the connector sends. For a subscription, that is the subscribe MID, not the data MID: pin {60,5} to subscribe lastTightening at revision 5. A refused pinned revision fails instead of stepping down. If fixedRevisions and an endpoint's revision pin the same MID to different revisions, the connector does not send the MID. A read or write publishes an error object on <topic>/res, and a subscription does not start.
Pin revisions for controllers that close the connection on a revision they do not support.
Unless fixedRevisions names them, the connector pins {1,1}, {900,1}, and {901,1}, so the connection handshake (MID 0001) goes out at revision 1. An endpoint's revision must match these default pins as well. For example, revision: 2 on a traceData endpoint also needs {900,2} in fixedRevisions.
Delivery
Each subscription publishes at most one message per 100 milliseconds, in arrival order. When the controller pushes faster, for example stored results after a reconnect, messages queue and arrive with a delay.
The queue is held in memory. Messages still in the queue are lost when the connection to the controller drops, when you disable the service, or when the Protocol Mapper or the agent that runs the connection restarts. Connectware acknowledges each message to the controller when it enters the queue, so the controller treats a lost message as delivered.
MID Group Reference
The following tables list the MID groups per operation and the MIDs they stand for. The Payload column shows whether the connector decodes the data or publishes it as a string.
Subscribe
alarm
0071
0070
Decoded
alarmAcknowledged
0074
Arrives with alarm (0070)
Decoded
alarmStatus
0076
Arrives with alarm (0070)
Decoded
automaticManualMode
0401
0400
String
digitalInputFunction
0221
0220
String
jobInfo
0035
0034
Decoded
jobLineControl
0121
0120
String
lastPowerMACSTighteningResultStationData
0106
0105
Decoded
lastTightening
0061
0060
Decoded
lockAtBatchDoneUpload
0022
0021
String
motorTuningResultData
0501
0500
String
multipleIdentifierResultParts
0152
0151
String
multiSpindleResult
0101
0100
String
multiSpindleStatus
0091
0090
String
openProtocolCommandsDisabled
0421
0420
String
plotData
0901
0008
Decoded
psetSelected
0015
0014
Decoded
relayFunction
0217
0216
String
selectorSocketInfo
0251
0250
String
statusExternallyMonitoredInputs
0211
0210
String
toolTagID
0262
0261
String
traceData
0900
0008
Decoded
userData
0242
0241
String
vin
0052
0051
Decoded
Read
autoDisableSettings
0410
0411
String
histogramUpload
0300
0301
String
ioDeviceStatus
0214
0215
String
jobDataUpload
0032
0033
String
jobIdUpload
0030
0031
String
keepAlive
9999
9999
String
modeDataUpload
2602
2603
String
modeIdUpload
2600
2601
String
oldTighteningResultUpload
0064
0065
Decoded
psetData
0012
0013
String
psetID
0010
0011
String
readTimeUpload
0080
0081
Decoded
toolDataUpload
0040
0041
String
toolTagID
0260
0262
String
Write
communicationStop
0003
selectPset
0018
setPsetBatchSize
0019
resetPsetBatchCounter
0020
parameterUserSetDownload
0025
selectJob
0038
jobRestart
0039
disableTool
0042
enableTool
0043
disconnectTool
0044
setCalibrationValue
0045
setPrimaryTool
0046
toolPairingHandling
0047
vinDownload
0050
setTime
0082
displayUserTextOnCompact
0110
displayUserTextOnGraph
0111
flashGreenLightOnTool
0113
abortJob
0127
jobBatchIncrement
0128
jobBatchDecrement
0129
jobOff
0130
setJobLineControlStart
0131
setJobLineAlert1
0132
setJobLineAlert2
0133
executeDynamicJob
0140
identifierDownload
0150
bypassIdentifier
0155
resetLatestIdentifier
0156
resetAllIdentifiers
0157
setExternallyControlledRelays
0200
setDigitalInputFunction
0224
resetDigitalInputFunction
0225
userDataDownload
0240
userDataDownloadWithOffset
0245
selectorControlGreenLights
0254
selectorControlRedLights
0255
controllerReboot
0270
motorTuning
0504
deviceCommand
2100
passwordRequest
2502
passwordResponse
2503
selectParameterSetDynamically
2505
selectMode
2606
Service Commissioning File Example
The following service commissioning file subscribes to tightening results, alarms, and torque curves, reads the parameter set IDs of the controller, and selects a parameter set.
Troubleshooting
The connector logs the following messages:
Read of 'psetID' failed: MID 10 rejected (error 97: …)
The controller refused the request. The error is also published on <topic>/res.
Write to 'selectJob' failed: MID 38 rejected (error 1: …)
The controller refused the command. The error is also published on <topic>/res.
Ignoring malformed fixedRevisions entry '…'
One fixedRevisions entry could not be read and was skipped.
Openprotocol client reported: …
A problem that does not end the connection.
Publishing MID 0061 revision 8 as received: …
A decoded MID arrived at a revision or in a layout the connector does not decode. It is published as a string.
Openprotocol watchdog: nothing received for …s, dropping the connection
The controller stopped sending. The connector reconnects.
Subscription … receives pushes faster than it publishes them: … queued, at least … s behind
100 or more messages are queued. See Delivery.
Unknown Openprotocol vendor '…'
device.vendor is not a supported vendor. The connection proceeds as AtlasCopco.
If a controller does not answer the connection handshake or closes the connection right after it, try the following:
Set
headerStyleto the other value. See Header Style.Pin the revisions the controller supports. See Pinning Revisions.
Set
genericMode: true. See Generic Mode.