For the complete documentation index, see llms.txt. This page is also available as Markdown.

Open Protocol Endpoint Properties

midGroup (string, enum)

Name of the MID group this endpoint addresses. Each group stands for the MIDs the Open Protocol specification defines for one function, e.g. lastTightening for the MID 0060 to 0063 quartet. Which groups are valid depends on the operation: subscribe groups are push subscriptions, read groups are request and reply MID pairs, write groups are command MIDs.

This element must be one of the following enum values:

  • abortJob

  • alarm

  • alarmAcknowledged

  • alarmStatus

  • autoDisableSettings

  • automaticManualMode

  • bypassIdentifier

  • communicationStop

  • controllerReboot

  • deviceCommand

  • digitalInputFunction

  • disableTool

  • disconnectTool

  • displayUserTextOnCompact

  • displayUserTextOnGraph

  • enableTool

  • executeDynamicJob

  • flashGreenLightOnTool

  • histogramUpload

  • identifierDownload

  • ioDeviceStatus

  • jobBatchDecrement

  • jobBatchIncrement

  • jobDataUpload

  • jobIdUpload

  • jobInfo

  • jobLineControl

  • jobOff

  • jobRestart

  • keepAlive

  • lastPowerMACSTighteningResultStationData

  • lastTightening

  • lockAtBatchDoneUpload

  • modeDataUpload

  • modeIdUpload

  • motorTuning

  • motorTuningResultData

  • multiSpindleResult

  • multiSpindleStatus

  • multipleIdentifierResultParts

  • oldTighteningResultUpload

  • openProtocolCommandsDisabled

  • parameterUserSetDownload

  • passwordRequest

  • passwordResponse

  • plotData

  • psetData

  • psetID

  • psetSelected

  • readTimeUpload

  • relayFunction

  • resetAllIdentifiers

  • resetDigitalInputFunction

  • resetLatestIdentifier

  • resetPsetBatchCounter

  • selectJob

  • selectMode

  • selectParameterSetDynamically

  • selectPset

  • selectorControlGreenLights

  • selectorControlRedLights

  • selectorSocketInfo

  • setCalibrationValue

  • setDigitalInputFunction

  • setExternallyControlledRelays

  • setJobLineAlert1

  • setJobLineAlert2

  • setJobLineControlStart

  • setPrimaryTool

  • setPsetBatchSize

  • setTime

  • statusExternallyMonitoredInputs

  • toolDataUpload

  • toolPairingHandling

  • toolTagID

  • traceData

  • userData

  • userDataDownload

  • userDataDownloadWithOffset

  • vin

  • vinDownload

Examples: "lastTightening", "selectPset", "psetData"

mid (integer)

Address one MID directly instead of naming a midGroup. For the MIDs no group covers: a controller may implement MIDs beyond the documented groups, and the Open Protocol specification reserves 1000 and up for vendor ranges. Whatever the specification defines for the number is applied automatically -- for a subscribe endpoint this is the data MID the controller pushes with, and its subscribe, acknowledge and unsubscribe MIDs are derived from it; for a read endpoint it is the request MID; for a write endpoint the command MID. Mutually exclusive with midGroup.

Example: 1000

Additional restrictions:

  • Minimum: 1

  • Maximum: 9999

replyMid (integer)

Which MID answers a read endpoint's request, for the request MIDs the specification does not pair with one. Only needed alongside mid, and only when the pairing is not documented -- a documented request MID derives its reply on its own.

Example: 1235

Additional restrictions:

  • Minimum: 1

  • Maximum: 9999

traceType (string, enum)

Which curve to subscribe for. Only used by the traceData group.

This element must be one of the following enum values:

  • angle

  • torque

  • current

  • gradient

  • stroke

  • force

Default: "torque"

functionNumber (integer)

Which single function to subscribe, for the groups that subscribe one function at a time instead of a stream: relayFunction takes the relay function number, digitalInputFunction the digital input function number. The controller's own tables define the numbering. Without it the subscription goes out without a function number, as the previous connector sent it, and receives the pushes of every function.

Example: 1

Additional restrictions:

  • Maximum: 999

revision (integer)

Send this endpoint's MID at exactly this revision, instead of starting at the connector's default revision and stepping down when the controller refuses it. A pin in the connection's fixedRevisions for the same MID must name the same revision.

Examples: 1, 8

Additional restrictions:

  • Minimum: 1

  • Maximum: 999

Last updated

Was this helpful?