LogoLogo
Contact Uscybus.io
Connectware 1.11.0
Connectware 1.11.0
  • Getting Started
    • Introduction
    • System Requirements
    • Connectware Admin UI
    • Basic Components of Connectware
    • Connecting your First Machine
      • Your First Service Commissioning File
  • Documentation
    • Installation and Upgrades
      • Installing Connectware
        • Installing Connectware (Kubernetes)
        • Installing Connectware (Docker)
      • Upgrading Connectware
        • Upgrading Connectware (Kubernetes)
          • Version-Specific Upgrades (Kubernetes)
        • Upgrading Connectware (Docker)
          • Version-Specific Upgrades (Docker)
      • Uninstalling Connectware
        • Uninstalling Connectware (Kubernetes)
        • Uninstalling Connectware (Docker)
      • Licensing
      • Restarting Connectware
    • User Management
      • Users and Roles View
      • Users
      • Roles
      • Permissions
      • Password Policy Rules
      • Default Admin User
      • MQTT Users
      • Adding a MQTT Publish Prefix for Users
      • Multi-Factor Authentication
      • Single Sign-On (SS0)
        • Single Sign-On with Microsoft Entra ID
        • Single Sign-On with LDAP
      • JSON Web Tokens
      • Access Permissions for Admin-UI
        • UI Access
        • Minimum Access Role Pages
    • Services
      • Service Overview
      • Service Resources View
        • Service Links View
        • Servers View
        • Containers View
        • Volumes View
        • Connections View
        • Endpoints View
        • Mappings View
      • Service Details View
      • Service Commissioning Files
        • Version
        • Description
        • Metadata
        • Parameters
        • Definitions
        • Resources
          • Cybus::Connection
          • Cybus::Container
            • Docker Problem with Network Changes
          • Cybus::Endpoint
          • Cybus::File
          • Cybus::IngressRoute
          • Cybus::Link
          • Cybus:Mapping
          • Cybus::Node
          • Cybus::Role
          • Cybus::Server
          • Cybus::User
          • Cybus::Volume
      • Setting Up and Configuring Services
        • Installing Services
        • Enabling Services
        • Updating Services
        • Disabling Services
        • Deleting Services
      • FlowSync
        • Example 1 - Node with Transaction Mode (HTTP)
        • Example 2 - Node Responds (HTTP)
        • Example 3 - Node with Error (HTTP)
        • Example 4 - Node with Timeout Error Code and Error Message (HTTP)
        • Example 5 - Full Transactional Data Flow (HTTP)
        • Example 6 - Full Transactional Data Flow (OPC UA)
      • ServiceID
      • Inter-Service Referencing
      • Deviations
      • Service Logs
        • Logs of Individual Services
        • Logs of All Services
      • Rule Engine
        • Data Processing Rules
        • Rule Sandbox
      • Shared Subscriptions
        • Setting Up Shared Subscriptions
    • Agents
      • Agents View
      • Installing Agents
        • Installing Agents via Docker
        • Installing Agents via Docker Compose
        • Installing Agents via Kubernetes
        • Using Mutual TLS for Agents
      • Registering Agents in Connectware
      • Using Agents
      • Monitoring Agents
      • Agents in Kubernetes
        • Adding Agents Inside your Connectware Installation
        • Remote Agents with the connectware-agent Helm Chart
        • Kubernetes Cluster Requirements for the connectware-agent Helm Chart
        • Installing Connectware Agents using the connectware-agent Helm Chart
        • Installing Connectware Agents without a License Key Using the connectware-agent Helm Chart
        • Upgrading the connectware-agent Helm Chart
        • Uninstalling Connectware agents with the connectware-agent Helm chart
        • Configuration Principles for the connectware-agent Helm Chart
        • Configuring Agents with the connectware-agent Helm Chart
          • Configuring Target Connectware for the connectware-agent Helm Chart
          • Configuring Agent Persistence for the connectware-agent Helm Chart
          • Configuring Compute Resources for the connectware-agent Helm Chart
          • Using a Custom Image Registry for the connectware-agent Helm Chart
          • Configuring Image Pull Policy for the connectware-agent Helm Chart
          • Using Mutual Transport Layer Security (mTLS) for agents with the connectware-agent Helm chart
          • Configuring image name and version for the connectware-agent Helm chart
          • Configuring Environment Variables for the connectware-agent Helm Chart
          • Configuring Labels and Annotations for the connectware-agent Helm Chart
          • Configuring podAntiAffinity for the connectware-agent Helm Chart
          • Assigning Agents to Kubernetes Nodes for the connectware-agent Helm Chart
          • Configuring Security Context for the connectware-agent Helm Chart
          • Controlling the Name of Kubernetes Objects for the connectware-agent Helm Chart
      • Troubleshooting Agents
    • Client Registry
      • Implicit Flow
      • Explicit Flow
      • Granting Access
    • Certificates
      • Certificates View
      • Adding Certificates
      • Removing Certificates
    • Monitoring
      • Data Explorer
      • Live Data
    • Node-RED Workbench
    • System Status
      • Info
      • Metrics
      • Status
      • Retrieving More System Information
      • System Health
    • Backup and Restore
      • Volumes
      • User Database
    • CybusMQ
      • Configuring CybusMQ
    • Connectware on Kubernetes
      • Connectware Helm Chart
      • Resizing Broker Volumes in Kubernetes
      • Configuring Core Services
      • LDAP Authentication
        • Configuring LDAP Authentication
        • Enabling TLS for LDAP Authentication
        • Manual Kubernetes Secret for LDAP Authentication Bind User
        • Customizing the Search Filter for LDAP Authentication
        • Customizing the User RDN for LDAP Authentication
      • Troubleshooting Connectware on Kubernetes
    • Environment Variables
    • Industry Protocol Details
      • ADS
        • ADS Connection Properties
        • ADS Endpoint Properties
      • BACnet
        • BACnet Connection Properties
        • BACnet Endpoint Properties
      • Custom Connectors
        • Developing Custom Connectors
        • Deploying Custom Connectors
        • Using Custom Connectors
      • EtherNet/IP
        • EtherNet/Ip Connection Properties
        • EtherNet/Ip Endpoint Properties
      • FOCAS
        • FOCAS Connection Properties
        • FOCAS Endpoint Properties
      • Hottinger Baldwin Messtechnik (HBM)
        • HBM Connection Properties
        • HBM Endpoint Properties
      • Heidenhain DNC
        • Heidenhain DNC Connection Properties
        • Heidenhain DNC Endpoint Properties
      • HTTP/REST
        • HTTP/REST Connection Properties
        • HTTP/REST Endpoint Properties
      • HTTP Server/Node
        • HTTP Server Properties
        • HTTP Node Properties
      • InfluxDB
        • InfluxDB Connection Properties
        • InfluxDB Endpoint Properties
      • Kafka
        • Kafka Connection Properties
        • Kafka Endpoint Properties
      • Modbus/TCP
        • Modbus/TCP Connection Properties
        • Modbus/TCP Endpoint Properties
      • MQTT
        • MQTT Connection Properties
        • MQTT Endpoint Properties
      • MSSQL
        • Mssql Connection Properties
        • Mssql Endpoint Properties
      • OPC DA
        • OPC DA Connection Properties
        • OPC DA Endpoint Properties
      • OPC UA
        • OPC UA Client
          • OPC UA Client Connection Properties
          • OPC UA Client Endpoint Properties
        • OPC UA Server
          • OPC UA Server Properties
          • OPC UA Node Properties
        • OPC UA Object Types
        • OPC UA Server References
          • OPC UA Reference Node
          • OPC UA Object Node
      • Siemens SIMATIC S7
        • Siemens S7 Connection Properties
        • Siemens S7 Endpoint Properties
      • Shdr
        • Shdr Connection Properties
        • Shdr Endpoint Properties
      • SINUMERIK
        • SINUMERIK Connection Properties
        • SINUMERIK Endpoint Properties
      • SOPAS
        • SOPAS Connection Properties
        • SOPAS Endpoint Properties
      • SQL
        • SQL Connection Properties
        • SQL Endpoint Properties
      • Werma WIN Ethernet
        • Werma WIN Ethernet Connection Properties
        • Werma WIN Ethernet Endpoint Properties
      • Systemstate
        • Systemstate Endpoint Properties
    • API Reference
      • User Management (API)
      • Client Registry (API)
      • Services (API)
      • Resources (API)
      • System Status (API)
      • Resource Status Tracking (HTTP API)
      • Industry Protocol Details (API)
    • Changelog
Powered by GitBook
LogoLogo

Cybus

  • Terms and Condition
  • Imprint
  • Data Privacy

© Copyright 2025, Cybus GmbH

On this page
  • host (string, required)
  • port (integer)
  • domain (string)
  • username (string, required)
  • password (string, required)
  • classId (string, required)
  • group (string)
  • timeout (integer)
  • comVersionMinor (integer)
  • connectionStrategy (object)

Was this helpful?

  1. Documentation
  2. Industry Protocol Details
  3. OPC DA

OPC DA Connection Properties

host (string, required)

Hostname or IP of the OPC DA server

Example: "192.168.0.1"

port (integer)

Port of the OPC DA server

Default: 135

domain (string)

Microsoft Windows domain of the OPC DA server

Default: "WORKGROUP"

username (string, required)

Username for OPC DA server (usually a user on the Windows computer of the OPC DA server)

Example: "user"

password (string, required)

Password for the user on the OPC DA server (usually the password of the Windows user)

Example: "user"

classId (string, required)

Microsoft Windows DCOM class ID of the OPC DA server

Default: "F8582CF2-88FB-11D0-B850-00C0F0104305"

Example: "F8582CF2-88FB-11D0-B850-00C0F0104305"

group (string)

OPC DA group name for the tags that will be accessed

Default: "Connectware Group"

Example: "Some Name"

timeout (integer)

Timeout, in milliseconds

Default: 5000

Examples: 2000, 5000, 10000

comVersionMinor (integer)

The minor part of the DCOM protocol version. The major protocol version is fixed at 5, but the minor version can be configured to choose between 5.7 (default) or the older 5.4.

Default: 7

Examples: 4, 7

connectionStrategy (object)

If a connection attempt fails, retries will be performed with increasing delay (waiting time) in between. The following parameters control how these delays behave.

Properties of the connectionStrategy object:

initialDelay (integer)

Delay (waiting time) of the first connection retry (in milliseconds). For subsequent retries, the delay will be increased according to the parameter incrementFactor which has a default value of 2.

Default: 1000

Additional restrictions:

  • Minimum: 1000

maxDelay (integer)

Maximum delay (waiting time) to wait until the next retry (in milliseconds). The delay (waiting time) for any subsequent connection retry will not be larger than this value. Must be strictly greater than initialDelay.

Default: 30000

incrementFactor (integer)

The factor used to increment initialDelay up to maxDelay. For example if initialDelay is set to 1000 and maxDelay to 5000 the values for the delay would be 1000, 2000, 4000, 5000.

Default: 2

Additional restrictions:

  • Minimum: 2

PreviousOPC DANextOPC DA Endpoint Properties

Last updated 2 months ago

Was this helpful?