SINUMERIK Endpoint Properties
type (string, enum)
type (string, enum)The type of subscription
This element must be one of the following enum values:
notifypoll
method (string, required)
method (string, required)The method to use
params (array)
params (array)The method parameters
pollInterval (integer)
pollInterval (integer)The amount of time between polls
Default: 1000
Additional restrictions:
Minimum:
1000
publishInterval (integer)
publishInterval (integer)Optional, sets the interval in which values are sent to their appropriate publish methods.
Default: 1000
samplingInterval (integer)
samplingInterval (integer)Integer, that sets the interval in which values are read from the server.
Default: 1000
maxNotificationsPerPublish (integer)
maxNotificationsPerPublish (integer)Sets the maximum number of monitor notifications that are in a single publish message of the OPC UA subscription. Setting this to a lower value will lead to more network traffic.
Default: 100
priority (integer)
priority (integer)Default: 10
requestedLifetimeCount (integer)
requestedLifetimeCount (integer)Default: 30
requestedMaxKeepAliveCount (integer)
requestedMaxKeepAliveCount (integer)Default: 10
retryMonitorTimeout (integer)
retryMonitorTimeout (integer)Default: 300000
Additional restrictions:
Minimum:
10000