HeidenhainConnection
agent
(string, required)
agent
(string, required)The name of the agent connecting to the CNC machine. Must match the name that is being used at the heidenhain-agent.exe executable.
Example: "heidenhain-agent-1"
ipAddress
(string)
ipAddress
(string)IP Address or hostname of the CNC machine
Examples: "localhost"
, "192.168.1.2"
cncType
(string, enum)
cncType
(string, enum)Type of the CNC control
This element must be one of the following enum values:
tnc640
itnc530
tnc426
Default: "tnc640"
Examples: "tnc640"
, "itnc530"
, "tnc426"
domain
(string)
domain
(string)Name of the edge communication domain
Default: "edge.cybus"
Example: "edge.cybus"
plcPassword
(string)
plcPassword
(string)Password to grant access to PLC functionality
Example: "807667"
tablePassword
(string)
tablePassword
(string)Password to grant access to TABLE functionality
Example: "807667"
usrPassword
(string)
usrPassword
(string)Password to grant access to USR functionality
Example: "807667"
sysPassword
(string)
sysPassword
(string)Password to grant access to SYS functionality
Example: "807667"
connectionStrategy
(object)
connectionStrategy
(object)If a connection attempt fails, retries will be performed with increasing delay (waiting time) in between. The following parameters control how these delays behave.
Properties of the connectionStrategy
object:
initialDelay
(integer)
initialDelay
(integer)Delay (waiting time) of the first connection retry (in milliseconds). For subsequent retries, the delay will be increased according to the parameter incrementFactor which has a default value of 2.
Default: 5000
Additional restrictions:
Minimum:
1000
maxDelay
(integer)
maxDelay
(integer)Maximum delay (waiting time) to wait until the next retry (in milliseconds). The delay (waiting time) for any subsequent connection retry will not be larger than this value. Must be strictly greater than initialDelay.
Default: 30000
incrementFactor
(integer)
incrementFactor
(integer)The factor used to increment initialDelay up to maxDelay. For example if initialDelay is set to 1000 and maxDelay to 5000 the values for the delay would be 1000, 2000, 4000, 5000.
Default: 2
Additional restrictions:
Minimum:
2
Last updated