LogoLogo
Contact Uscybus.io
Connectware 1.10.0
Connectware 1.10.0
  • Getting Started
    • Introduction
    • Installing Connectware
      • System Requirements
      • Acquiring your License Key
      • Installing Connectware on Docker
      • Installing Connectware on Kubernetes
    • Connectware Admin UI
    • Basic Components of Connectware
    • Connecting your First Machine
      • Your First Service Commissioning File
  • Documentation
    • Services
      • Service Overview
      • Service Resources View
        • Service Links View
        • Servers View
        • Containers View
        • Volumes View
        • Connections View
        • Endpoints View
        • Mappings View
      • Service Details View
      • Service Commissioning Files
        • Structure of Service Commissioning Files
          • Version
          • Description
          • Metadata
          • Parameters
          • Definitions
          • Resources
            • Cybus::Connection
            • Cybus::Endpoint
            • Cybus:Mapping
            • Cybus::Container
              • Docker problem with network changes
            • Cybus::Link
            • Cybus::IngressRoute
            • Cybus::User
            • Cybus::Role
            • Cybus::Volume
            • Cybus::File
            • Cybus::Server
            • Cybus::Node
      • Setting Up and Configuring Services
        • Installing Services
        • Enabling Services
        • Updating Services
        • Disabling Services
        • Deleting Services
      • FlowSync
        • Example 1 - Node with Transaction Mode (HTTP)
        • Example 2 - Node Responds (HTTP)
        • Example 3 - Node with Error (HTTP)
        • Example 4 - Node with Timeout Error Code and Error Message (HTTP)
        • Example 5 - Full Transactional Data Flow (HTTP)
        • Example 6 - Full Transactional Data Flow (OPC UA)
      • ServiceID
      • Inter-Service Referencing
      • Deviation
      • Service Logs
        • Logs of Individual Services
        • Logs of All Services
      • Rule Engine
        • Data Processing Rules
        • Rule Sandbox
      • Shared Subscriptions
        • Setting Up Shared Subscriptions
    • User Management
      • Users and Roles View
      • Users
      • Roles
      • Permissions
      • Password Policy Rules
      • Default Admin User
      • MQTT Users
      • Adding a MQTT Publish Prefix for Users
      • Multi-Factor Authentication
      • Single Sign-On (SS0)
        • Single Sign-On with Microsoft Entra ID
        • Single Sign-On with LDAP
      • Long lived JSON Web Tokens
      • Access Permissions for Admin-UI
        • UI Access
        • Minimum Access Role Pages
    • Client Registry
      • Implicit Flow
      • Explicit Flow
      • Granting Access
    • Certificates
    • Monitoring
      • Data Explorer
      • Live Data
    • Workbench
      • Flows in Git Repositories
    • System Status
      • Info
      • Metrics
      • Status
      • Retrieving More System Information
      • System Health
    • Backup and Restore
      • Volumes
      • User Database
    • Environment Variables
    • Agents
      • Agents View
      • Installing Agents
        • Installing Agents via Docker
        • Installing Agents via Docker Compose
        • Installing Agents via Kubernetes
        • Using Mutual TLS for Agents
      • Registering Agents in Connectware
      • Using Agents
      • Monitoring Agents
      • Troubleshooting Agents
    • Industry Protocol Details
      • ADS
        • ADS Connection Properties
        • ADS Endpoint Properties
      • BACnet
        • BACnet Connection Properties
        • BACnet Endpoint Properties
      • EtherNet/IP
        • EtherNet/Ip Connection Properties
        • EtherNet/Ip Endpoint Properties
      • FOCAS
        • FOCAS Connection Properties
        • FOCAS Endpoint Properties
      • Generic VRPC
        • Generic VRPC Connection Properties
        • Generic VRPC Endpoint Properties
      • Hottinger Baldwin Messtechnik (HBM)
        • HBM Connection Properties
        • HBM Endpoint Properties
      • Heidenhain DNC
        • Heidenhain DNC Connection Properties
        • Heidenhain DNC Endpoint Properties
      • HTTP/REST
        • HTTP/REST Connection Properties
        • HTTP/REST Endpoint Properties
      • HTTP Server/Node
        • HTTP Server Properties
        • HTTP Node Properties
      • InfluxDB
        • InfluxDB Connection Properties
        • InfluxDB Endpoint Properties
      • Kafka
        • Kafka Connection Properties
        • Kafka Endpoint Properties
      • Modbus/TCP
        • Modbus/TCP Connection Properties
        • Modbus/TCP Endpoint Properties
      • MQTT
        • MQTT Connection Properties
        • MQTT Endpoint Properties
      • MSSQL
        • Mssql Connection Properties
        • Mssql Endpoint Properties
      • OPC DA
        • OPC DA Connection Properties
        • OPC DA Endpoint Properties
      • OPC UA
        • OPC UA Client
          • OPC UA Client Connection Properties
          • OPC UA Client Endpoint Properties
        • OPC UA Server
          • OPC UA Server Properties
          • OPC UA Node Properties
        • OPC UA Object Types
        • OPC UA Server References
          • OPC UA Reference Node
          • OPC UA Object Node
      • Siemens SIMATIC S7
        • Siemens S7 Connection Properties
        • Siemens S7 Endpoint Properties
      • Shdr
        • Shdr Connection Properties
        • Shdr Endpoint Properties
      • SINUMERIK
        • SINUMERIK Connection Properties
        • SINUMERIK Endpoint Properties
      • SOPAS
        • SOPAS Connection Properties
        • SOPAS Endpoint Properties
      • SQL
        • SQL Connection Properties
        • SQL Endpoint Properties
      • Werma WIN Ethernet
        • Werma WIN Ethernet Connection Properties
        • Werma WIN Ethernet Endpoint Properties
      • Systemstate
        • Systemstate Connection Properties
        • Systemstate Endpoint Properties
    • Connectware Licensing
    • API Reference
      • User Management (API)
      • Client Registry (API)
      • Services (API)
      • Resources (API)
      • System Status (API)
      • Industry Protocol Details (API)
    • Changelog
      • General changes from 0.x to 1.0
        • Upgrading from 0.x to 1.0
    • Upgrade Guide
      • Upgrading from 1.x to 1.7.0
      • Upgrading from 1.x to 1.5.0
Powered by GitBook
LogoLogo

Cybus

  • Terms and Condition
  • Imprint
  • Data Privacy

© Copyright 2025, Cybus GmbH

On this page
  • method (string, enum, required)
  • interval (integer)
  • cronExpression (string)
  • slctData (integer)
  • addressType (integer)
  • dataType (integer, enum)
  • spindleNumber (integer)
  • type (integer)
  • block (integer)
  • numGcd (integer)
  • addressStart (integer)
  • addressEnd (integer)
  • dataLength (integer)

Was this helpful?

  1. Documentation
  2. Industry Protocol Details
  3. FOCAS

FOCAS Endpoint Properties

method (string, enum, required)

The method to run on the device

This element must be one of the following enum values:

  • cnc_sysinfo

  • cnc_statinfo2

  • cnc_rdprgnum

  • cnc_exeprgname

  • cnc_rdopnlsgnl

  • pmc_rdpmcrng

  • cnc_rdspeed

  • cnc_rdspload

  • cnc_rdgcode

  • program_download

Example: "cnc_sysinfo"

interval (integer)

The interval between reads (only for the subscribe operation)

Default: 1000

Additional restrictions:

  • Minimum: 500

cronExpression (string)

The Cron expression used to poll the endpoint. (For examples, see: https://github.com/node-cron/node-cron)

Examples: "1,2,4,5 * * * *", "1-5 * * * *", "*/2 * * * *", "* * * January,September Sunday"

slctData (integer)

Specify the data select flag (only applies for the cnc_rdopnlsgnl method)

Default: 32767

Additional restrictions:

  • Maximum: 32767

addressType (integer)

Specify the identification code corresponding to the kind of the PMC address (only applies for the pmc_rdpmcrng method)

Default: 0

Additional restrictions:

  • Maximum: 13

dataType (integer, enum)

Specify the type of the PMC data or CNC feed rate/spindle speed (only applies for the methods pmc_rdpmcrng and cnc_rdspeed), which can be byte (0), word (1), long (2), float32 (4) or float64 (5). float32 and float64 apply for 30i-B Series/0i-F/PMi-A only. For method cnc_rdspeed valid values are 0 (feed rate), 1 (spindle speed), -1 (all)

This element must be one of the following enum values:

  • -1

  • 0

  • 1

  • 2

  • 4

  • 5

Default: 0

spindleNumber (integer)

Specify spindle number to read. from 1 up to 8 for Series 30i, 0i-D/F. 1 up to 4 for Series 15/15i, 16i/18i/21i, 16i/18i/21i, 0i-A/B/C. And only number 1 for Power Mate i-D

Default: 1

Additional restrictions:

  • Minimum: 1

  • Maximum: 8

type (integer)

Specify the group of G code. Only applies for method cnc_rdgcode. Series 15i: goes from 0 to 18,24,25,27/-1/100 to 103/-2. For Series 30i, 0i-D/F, PMi-A: goes from 0 to 36/-1/100 to 103/-2

Default: -1

Additional restrictions:

  • Minimum: -2

  • Maximum: 103

block (integer)

Specify the block to be read. 0 -> previus block, 1 -> active block, 2 -> next block. Only applies for method cnc_rdgcode

Default: 1

Additional restrictions:

  • Maximum: 2

numGcd (integer)

number of G code data to be read. Only applies for method cnc_rdgcode

Default: 1

Additional restrictions:

  • Minimum: 1

addressStart (integer)

Specify the start PMC address number (only applies for the pmc_rdpmcrng method)

Default: 0

addressEnd (integer)

Specify the end PMC address number (only applies for the pmc_rdpmcrng method)

Default: 0

dataLength (integer)

Specify the data block length (only applies for the pmc_rdpmcrng method)

Default: 8

Additional restrictions:

  • Minimum: 8

PreviousFOCAS Connection PropertiesNextGeneric VRPC

Last updated 4 months ago

Was this helpful?