LogoLogo
Contact Uscybus.io
Connectware 1.10.0
Connectware 1.10.0
  • Getting Started
    • Introduction
    • Installing Connectware
      • System Requirements
      • Acquiring your License Key
      • Installing Connectware on Docker
      • Installing Connectware on Kubernetes
    • Connectware Admin UI
    • Basic Components of Connectware
    • Connecting your First Machine
      • Your First Service Commissioning File
  • Documentation
    • Services
      • Service Overview
      • Service Resources View
        • Service Links View
        • Servers View
        • Containers View
        • Volumes View
        • Connections View
        • Endpoints View
        • Mappings View
      • Service Details View
      • Service Commissioning Files
        • Structure of Service Commissioning Files
          • Version
          • Description
          • Metadata
          • Parameters
          • Definitions
          • Resources
            • Cybus::Connection
            • Cybus::Endpoint
            • Cybus:Mapping
            • Cybus::Container
              • Docker problem with network changes
            • Cybus::Link
            • Cybus::IngressRoute
            • Cybus::User
            • Cybus::Role
            • Cybus::Volume
            • Cybus::File
            • Cybus::Server
            • Cybus::Node
      • Setting Up and Configuring Services
        • Installing Services
        • Enabling Services
        • Updating Services
        • Disabling Services
        • Deleting Services
      • FlowSync
        • Example 1 - Node with Transaction Mode (HTTP)
        • Example 2 - Node Responds (HTTP)
        • Example 3 - Node with Error (HTTP)
        • Example 4 - Node with Timeout Error Code and Error Message (HTTP)
        • Example 5 - Full Transactional Data Flow (HTTP)
        • Example 6 - Full Transactional Data Flow (OPC UA)
      • ServiceID
      • Inter-Service Referencing
      • Deviation
      • Service Logs
        • Logs of Individual Services
        • Logs of All Services
      • Rule Engine
        • Data Processing Rules
        • Rule Sandbox
      • Shared Subscriptions
        • Setting Up Shared Subscriptions
    • User Management
      • Users and Roles View
      • Users
      • Roles
      • Permissions
      • Password Policy Rules
      • Default Admin User
      • MQTT Users
      • Adding a MQTT Publish Prefix for Users
      • Multi-Factor Authentication
      • Single Sign-On (SS0)
        • Single Sign-On with Microsoft Entra ID
        • Single Sign-On with LDAP
      • Long lived JSON Web Tokens
      • Access Permissions for Admin-UI
        • UI Access
        • Minimum Access Role Pages
    • Client Registry
      • Implicit Flow
      • Explicit Flow
      • Granting Access
    • Certificates
    • Monitoring
      • Data Explorer
      • Live Data
    • Workbench
      • Flows in Git Repositories
    • System Status
      • Info
      • Metrics
      • Status
      • Retrieving More System Information
      • System Health
    • Backup and Restore
      • Volumes
      • User Database
    • Environment Variables
    • Agents
      • Agents View
      • Installing Agents
        • Installing Agents via Docker
        • Installing Agents via Docker Compose
        • Installing Agents via Kubernetes
        • Using Mutual TLS for Agents
      • Registering Agents in Connectware
      • Using Agents
      • Monitoring Agents
      • Troubleshooting Agents
    • Industry Protocol Details
      • ADS
        • ADS Connection Properties
        • ADS Endpoint Properties
      • BACnet
        • BACnet Connection Properties
        • BACnet Endpoint Properties
      • EtherNet/IP
        • EtherNet/Ip Connection Properties
        • EtherNet/Ip Endpoint Properties
      • FOCAS
        • FOCAS Connection Properties
        • FOCAS Endpoint Properties
      • Generic VRPC
        • Generic VRPC Connection Properties
        • Generic VRPC Endpoint Properties
      • Hottinger Baldwin Messtechnik (HBM)
        • HBM Connection Properties
        • HBM Endpoint Properties
      • Heidenhain DNC
        • Heidenhain DNC Connection Properties
        • Heidenhain DNC Endpoint Properties
      • HTTP/REST
        • HTTP/REST Connection Properties
        • HTTP/REST Endpoint Properties
      • HTTP Server/Node
        • HTTP Server Properties
        • HTTP Node Properties
      • InfluxDB
        • InfluxDB Connection Properties
        • InfluxDB Endpoint Properties
      • Kafka
        • Kafka Connection Properties
        • Kafka Endpoint Properties
      • Modbus/TCP
        • Modbus/TCP Connection Properties
        • Modbus/TCP Endpoint Properties
      • MQTT
        • MQTT Connection Properties
        • MQTT Endpoint Properties
      • MSSQL
        • Mssql Connection Properties
        • Mssql Endpoint Properties
      • OPC DA
        • OPC DA Connection Properties
        • OPC DA Endpoint Properties
      • OPC UA
        • OPC UA Client
          • OPC UA Client Connection Properties
          • OPC UA Client Endpoint Properties
        • OPC UA Server
          • OPC UA Server Properties
          • OPC UA Node Properties
        • OPC UA Object Types
        • OPC UA Server References
          • OPC UA Reference Node
          • OPC UA Object Node
      • Siemens SIMATIC S7
        • Siemens S7 Connection Properties
        • Siemens S7 Endpoint Properties
      • Shdr
        • Shdr Connection Properties
        • Shdr Endpoint Properties
      • SINUMERIK
        • SINUMERIK Connection Properties
        • SINUMERIK Endpoint Properties
      • SOPAS
        • SOPAS Connection Properties
        • SOPAS Endpoint Properties
      • SQL
        • SQL Connection Properties
        • SQL Endpoint Properties
      • Werma WIN Ethernet
        • Werma WIN Ethernet Connection Properties
        • Werma WIN Ethernet Endpoint Properties
      • Systemstate
        • Systemstate Connection Properties
        • Systemstate Endpoint Properties
    • Connectware Licensing
    • API Reference
      • User Management (API)
      • Client Registry (API)
      • Services (API)
      • Resources (API)
      • System Status (API)
      • Industry Protocol Details (API)
    • Changelog
      • General changes from 0.x to 1.0
        • Upgrading from 0.x to 1.0
    • Upgrade Guide
      • Upgrading from 1.x to 1.7.0
      • Upgrading from 1.x to 1.5.0
Powered by GitBook
LogoLogo

Cybus

  • Terms and Condition
  • Imprint
  • Data Privacy

© Copyright 2025, Cybus GmbH

On this page
  • scheme (string, enum)
  • host (string, required)
  • port (integer, required)
  • prefix (string)
  • headers (object)
  • query (object)
  • auth (object)
  • oauthClientCredentials (object)
  • probeInterval (integer)
  • probeTimeout (integer)
  • probePath (string)
  • probeMethod (string, enum)
  • mutualAuthentication (boolean)
  • trustAllCertificates (boolean)
  • caCert (string)
  • clientCert (string)
  • clientPrivateKey (string)
  • connectionStrategy (object)

Was this helpful?

  1. Documentation
  2. Industry Protocol Details
  3. HTTP/REST

HTTP/REST Connection Properties

scheme (string, enum)

Transport scheme to be used

This element must be one of the following enum values:

  • http

  • https

Example: "https"

host (string, required)

Domain name or IP Address of the server to connect to

Examples: "126.4.10.52", "example.org"

port (integer, required)

HTTP Port to use, usually 80 or 443

Default: 443

Example: 15200

prefix (string)

Path prefix that is applied to all endpoints

Default: ""

Example: "/api/v1"

headers (object)

HTTP Headers that are added to all requests

Default:

{}

Example: {"Content-type":"application/json"}

query (object)

Query variables that are added to all requests

Example: {"foo":"bar"}

auth (object)

Credentials for Basic Auth

Properties of the auth object:

username (string)

password (string)

oauthClientCredentials (object)

Oauth Client Credentials flow configuration

Properties of the oauthClientCredentials object:

auth_url (string, required)

client_id (string, required)

client_secret (string, required)

grant_type (string)

Default: "client_credentials"

audience (string)

probeInterval (integer)

Interval in milliseconds to check if connection is still there

Default: 10000

probeTimeout (integer)

Timeout in milliseconds after which the probe request gets abort. (Defaults to 0, because of backwards compatibility - no timeout)

Default: 0

Examples: 0, 1000, 3000

probePath (string)

The path that should be used to check the health of the server

Default: "/"

probeMethod (string, enum)

The HTTP method to use for contacting the configured Probe URL

This element must be one of the following enum values:

  • GET

  • HEAD

Default: "HEAD"

mutualAuthentication (boolean)

If true, a full certificate chain including client certificate is expected to connect properly with validated certificates.

Default: false

Examples: true, false

trustAllCertificates (boolean)

If true, all server certificates will be accepted, regardless of whether they can be validated or not. Use this option if self-signed server certificates should be accepted, or if there are other reasons which prevent this client to validate the certificates.

Default: false

Examples: true, false

caCert (string)

The root CA certificate as Base64 encoded PEM file content

clientCert (string)

The client certificate as Base64 encoded PEM CRT file content

clientPrivateKey (string)

The client private key as Base64 encoded PEM CRT file content

connectionStrategy (object)

If a connection attempt fails, retries will be performed with increasing delay (waiting time) in between. The following parameters control how these delays behave.

Properties of the connectionStrategy object:

initialDelay (integer)

Delay (waiting time) of the first connection retry (in milliseconds). For subsequent retries, the delay will be increased according to the parameter incrementFactor which has a default value of 2.

Default: 1000

Additional restrictions:

  • Minimum: 1000

maxDelay (integer)

Maximum delay (waiting time) to wait until the next retry (in milliseconds). The delay (waiting time) for any subsequent connection retry will not be larger than this value. Must be strictly greater than initialDelay.

Default: 30000

incrementFactor (integer)

The factor used to increment initialDelay up to maxDelay. For example if initialDelay is set to 1000 and maxDelay to 5000 the values for the delay would be 1000, 2000, 4000, 5000.

Default: 2

Additional restrictions:

  • Minimum: 2

PreviousHTTP/RESTNextHTTP/REST Endpoint Properties

Last updated 4 months ago

Was this helpful?