This example shows an entire BAZ setup expressed within a single commissioning file and by using explicit topics on the endpoint resources (obsoleting a mapping resource).
The example below uses an additional Docker image provided by Cybus that requires a suitable license. You can check the current capabilities and permissions of your Connectware license in the Cybus Portal (). If your license is not eligible to use the example Docker image, please contact Cybus Sales ().
description: >
Entire simulated machining demo setup
metadata:
name: Simulated Machining Center
icon: https://www.cybus.io/wp-content/themes/cybus/img/product-slide-img.png
provider: cybus
homepage: https://www.cybus.io
version: 2.0.0
parameters:
modbusPort:
type: integer
default: 10502
dockerBridgeNetworkIp:
type: string
default: 172.17.0.1
description: The IP address of the docker bridge network gateway, see "docker network inspect bridge"
definitions:
CYBUS_MQTT_ROOT: cybus/baz-simulator
defaultModbusAddress:
fc: 3
length: 2
interval: 1000
dataType: uint16BE
resources:
machineSimulator:
type: Cybus::Container
properties:
image: registry.cybus.io/cybus-services/baz-machine-simulator:0.0.1
ports:
- !sub '${modbusPort}:10502/tcp'
modbusConnection:
type: Cybus::Connection
properties:
protocol: Modbus
targetState: connected
connection:
host: !ref dockerBridgeNetworkIp
port: !ref modbusPort
currentState:
type: Cybus::Endpoint
properties:
protocol: Modbus
connection: !ref modbusConnection
topic: current-state
subscribe: !merge
defaultModbusAddress:
address: 0
currentTool:
type: Cybus::Endpoint
properties:
protocol: Modbus
connection: !ref modbusConnection
topic: current-tool
subscribe: !merge
defaultModbusAddress:
address: 2
coolantLevel:
type: Cybus::Endpoint
properties:
protocol: Modbus
connection: !ref modbusConnection
topic: coolant-level
subscribe: !merge
defaultModbusAddress:
address: 4
spindleSpeed:
type: Cybus::Endpoint
properties:
protocol: Modbus
connection: !ref modbusConnection
topic: spindle-speed
subscribe: !merge
defaultModbusAddress:
address: 6
dashboard:
type: Cybus::Container
properties:
image: registry.cybus.io/cybus-services/baz-dashboard:0.2.3
volumes:
- !sub '${dashboardData}:/root/.node-red'
environment:
MQTT_HOST: !ref Cybus::MqttHost
MQTT_USER: !ref Cybus::MqttUser
MQTT_PASS: !ref Cybus::MqttPassword
MQTT_PORT: !ref Cybus::MqttPort
HTTP_ROOT: /
dashboardData:
type: Cybus::Volume
dashboardRoute:
type: Cybus::IngressRoute
properties:
container: !ref dashboard
type: http
slug: dashboard
target:
path: /
port: 1880
dashboardLink:
type: Cybus::Link
properties:
ingressRoute: !ref dashboardRoute
href: ui/