LogoLogo
Contact Uscybus.io
Connectware 1.10.0
Connectware 1.10.0
  • Getting Started
    • Introduction
    • Installing Connectware
      • System Requirements
      • Acquiring your License Key
      • Installing Connectware on Docker
      • Installing Connectware on Kubernetes
    • Connectware Admin UI
    • Basic Components of Connectware
    • Connecting your First Machine
      • Your First Service Commissioning File
  • Documentation
    • Services
      • Service Overview
      • Service Resources View
        • Service Links View
        • Servers View
        • Containers View
        • Volumes View
        • Connections View
        • Endpoints View
        • Mappings View
      • Service Details View
      • Service Commissioning Files
        • Structure of Service Commissioning Files
          • Version
          • Description
          • Metadata
          • Parameters
          • Definitions
          • Resources
            • Cybus::Connection
            • Cybus::Endpoint
            • Cybus:Mapping
            • Cybus::Container
              • Docker problem with network changes
            • Cybus::Link
            • Cybus::IngressRoute
            • Cybus::User
            • Cybus::Role
            • Cybus::Volume
            • Cybus::File
            • Cybus::Server
            • Cybus::Node
      • Setting Up and Configuring Services
        • Installing Services
        • Enabling Services
        • Updating Services
        • Disabling Services
        • Deleting Services
      • FlowSync
        • Example 1 - Node with Transaction Mode (HTTP)
        • Example 2 - Node Responds (HTTP)
        • Example 3 - Node with Error (HTTP)
        • Example 4 - Node with Timeout Error Code and Error Message (HTTP)
        • Example 5 - Full Transactional Data Flow (HTTP)
        • Example 6 - Full Transactional Data Flow (OPC UA)
      • ServiceID
      • Inter-Service Referencing
      • Deviation
      • Service Logs
        • Logs of Individual Services
        • Logs of All Services
      • Rule Engine
        • Data Processing Rules
        • Rule Sandbox
      • Shared Subscriptions
        • Setting Up Shared Subscriptions
    • User Management
      • Users and Roles View
      • Users
      • Roles
      • Permissions
      • Password Policy Rules
      • Default Admin User
      • MQTT Users
      • Adding a MQTT Publish Prefix for Users
      • Multi-Factor Authentication
      • Single Sign-On (SS0)
        • Single Sign-On with Microsoft Entra ID
        • Single Sign-On with LDAP
      • Long lived JSON Web Tokens
      • Access Permissions for Admin-UI
        • UI Access
        • Minimum Access Role Pages
    • Client Registry
      • Implicit Flow
      • Explicit Flow
      • Granting Access
    • Certificates
    • Monitoring
      • Data Explorer
      • Live Data
    • Workbench
      • Flows in Git Repositories
    • System Status
      • Info
      • Metrics
      • Status
      • Retrieving More System Information
      • System Health
    • Backup and Restore
      • Volumes
      • User Database
    • Environment Variables
    • Agents
      • Agents View
      • Installing Agents
        • Installing Agents via Docker
        • Installing Agents via Docker Compose
        • Installing Agents via Kubernetes
        • Using Mutual TLS for Agents
      • Registering Agents in Connectware
      • Using Agents
      • Monitoring Agents
      • Troubleshooting Agents
    • Industry Protocol Details
      • ADS
        • ADS Connection Properties
        • ADS Endpoint Properties
      • BACnet
        • BACnet Connection Properties
        • BACnet Endpoint Properties
      • EtherNet/IP
        • EtherNet/Ip Connection Properties
        • EtherNet/Ip Endpoint Properties
      • FOCAS
        • FOCAS Connection Properties
        • FOCAS Endpoint Properties
      • Generic VRPC
        • Generic VRPC Connection Properties
        • Generic VRPC Endpoint Properties
      • Hottinger Baldwin Messtechnik (HBM)
        • HBM Connection Properties
        • HBM Endpoint Properties
      • Heidenhain DNC
        • Heidenhain DNC Connection Properties
        • Heidenhain DNC Endpoint Properties
      • HTTP/REST
        • HTTP/REST Connection Properties
        • HTTP/REST Endpoint Properties
      • HTTP Server/Node
        • HTTP Server Properties
        • HTTP Node Properties
      • InfluxDB
        • InfluxDB Connection Properties
        • InfluxDB Endpoint Properties
      • Kafka
        • Kafka Connection Properties
        • Kafka Endpoint Properties
      • Modbus/TCP
        • Modbus/TCP Connection Properties
        • Modbus/TCP Endpoint Properties
      • MQTT
        • MQTT Connection Properties
        • MQTT Endpoint Properties
      • MSSQL
        • Mssql Connection Properties
        • Mssql Endpoint Properties
      • OPC DA
        • OPC DA Connection Properties
        • OPC DA Endpoint Properties
      • OPC UA
        • OPC UA Client
          • OPC UA Client Connection Properties
          • OPC UA Client Endpoint Properties
        • OPC UA Server
          • OPC UA Server Properties
          • OPC UA Node Properties
        • OPC UA Object Types
        • OPC UA Server References
          • OPC UA Reference Node
          • OPC UA Object Node
      • Siemens SIMATIC S7
        • Siemens S7 Connection Properties
        • Siemens S7 Endpoint Properties
      • Shdr
        • Shdr Connection Properties
        • Shdr Endpoint Properties
      • SINUMERIK
        • SINUMERIK Connection Properties
        • SINUMERIK Endpoint Properties
      • SOPAS
        • SOPAS Connection Properties
        • SOPAS Endpoint Properties
      • SQL
        • SQL Connection Properties
        • SQL Endpoint Properties
      • Werma WIN Ethernet
        • Werma WIN Ethernet Connection Properties
        • Werma WIN Ethernet Endpoint Properties
      • Systemstate
        • Systemstate Connection Properties
        • Systemstate Endpoint Properties
    • Connectware Licensing
    • API Reference
      • User Management (API)
      • Client Registry (API)
      • Services (API)
      • Resources (API)
      • System Status (API)
      • Industry Protocol Details (API)
    • Changelog
      • General changes from 0.x to 1.0
        • Upgrading from 0.x to 1.0
    • Upgrade Guide
      • Upgrading from 1.x to 1.7.0
      • Upgrading from 1.x to 1.5.0
Powered by GitBook
LogoLogo

Cybus

  • Terms and Condition
  • Imprint
  • Data Privacy

© Copyright 2025, Cybus GmbH

On this page

Was this helpful?

  1. Documentation
  2. Agents

Registering Agents in Connectware

PreviousUsing Mutual TLS for AgentsNextUsing Agents

Last updated 4 months ago

Was this helpful?

Registering agents in Connectware enables them to connect to Connectware.

You must register agents in any of the following cases:

  • The agent is being started for the first time.

  • The persisted credentials have been deleted.

  • The agent is unable to log into Connectware with its cached credentials.

In all other cases, registering agents is not required and the agent will run using the stored credentials from the volume it is mounted on.

If multiple agents are to run on the same computer, each agent must use its own volume mount, otherwise the agents will overwrite each other's credentials.

During the initial deployment, the registration process is as follows:

  1. Start the agent container. The container's console log should display messages like this:

{"level":30,"time":1590665714502,"msg":"Starting in distributed (edge) mode","pid":6,"hostname":"someHost","v":1}
{"level":30,"time":1590665714568,"msg":"Asking for Connectware registration at 1.2.3.4 with newly generated credentials...","pid":6,"hostname":"someHost","v":1}
{"level":30,"time":1590665714568,"msg":"The registration process must be finished using the web-interface.","pid":6,"hostname":"someHost","v":1}
{"level":30,"time":1590665714568,"msg":"Navigate to \"User Management -> Client Registry\", click unlock and authorize this client.","pid":6,"hostname":"someHost","v":1}
{"level":30,"time":1590665714568,"msg":"Username: cybus-sample-agent, pairing ID (should match in UI): a82123","pid":6,"hostname":"someHost","v":1}

If you encounter a 409 Conflict error, it means that there is a registration conflict that must be resolved. For more information, see .

  1. To complete the agent registration, log into Connectware and authorize the client through the Client Registry view. For more information, see .

In addition to the agent name, you can also compare the Pairing ID to verify that you are granting access to the correct agent instance.

Client Registry
User Registration Conflict (409 Conflict)