OpcuaServer
port
(integer)
port
(integer)Port of the listening socket
Default: 4841
Example: 4841
maxSessions
(integer)
maxSessions
(integer)Max Sessions allowed by user
Default: 20
Example: 1000
maxConnections
(integer)
maxConnections
(integer)Max Connections allowed for a single endpoint to prevent DDoS attacks
Default: 20
Example: 1000
resourcePath
(string)
resourcePath
(string)Resource Path of the OPC Server. This must be added to the OPC UA connection URN of the client
Default: "/UA/CybusOpcuaServer"
Examples: "/UA/CybusOpcuaServer"
, "/My/IndividualName"
alternateHostname
(string)
alternateHostname
(string)This setting is deprecated, has been renamed into 'hostname', and will be removed in a future release
Examples: "10.20.30.40"
, "my.connectware-host.company.com"
hostname
(string)
hostname
(string)The hostname by which the Connectware with the OPC UA server will be reachable on the system. This can be either an IP address or a DNS name.
Examples: "10.20.30.40"
, "my.connectware-host.company.com"
applicationUri
(string)
applicationUri
(string)The application URI is used to define the namespace name of the Connectware defined NodeIds
Default: "urn:cybus:opcua:server:1"
Example: "urn:cybus:opcua:server:1"
allowAnonymous
(boolean)
allowAnonymous
(boolean)If true, usage of anonymous access token is allowed. In that case, OPC UA clients are allowed to connect without any authentication. Note: This is a high security risk and must not be used in production deployments.
Default: false
Example: true
certificateFile
(string)
certificateFile
(string)Absolute path to the server certificate file
Default: "/connectware_certs/cybus_server.crt"
Example: "/connectware_certs/cybus_server.crt"
privateKeyFile
(string)
privateKeyFile
(string)Absolute path to the server private key file
Default: "/connectware_certs/cybus_server.key"
Example: "/connectware_certs/cybus_server.key"
securityPolicies
(array)
securityPolicies
(array)Defines the list of OPC UA securityPolicies that will be available on the server. Note: The policy "None" is a high security risk and must not be used in production deployments.
The object is an array with all elements of the type string
.
Each element of the array must be one of the following enum values:
Basic256Sha256
None
Default:
Example: "[\"Basic256Sha256\", \"None\"]"
nodesetFiles
(array)
nodesetFiles
(array)Predefined Nodeset files to load on startup
The object is an array with all elements of the type string
.
Each element of the array must be one of the following enum values:
standard
di
ia
machinery
machineTool
packML
robotics
Opc.Ua.PlasticsRubber.GeneralTypes.NodeSet2.xml
Opc.Ua.PlasticsRubber.IMM2MES.NodeSet2.xml
Opc.Ua.PLCopen.NodeSet2.xml
securityModes
(array)
securityModes
(array)Defines the list of OPC UA security modes which an OPC client can use to establish a connection to the Cybus OPC UA server
The object is an array with all elements of the type string
.
Each element of the array must be one of the following enum values:
Invalid
None
Sign
SignAndEncrypt
Default:
Example: "[\"None\", \"SignAndEncrypt\"]"
database
(object)
database
(object)Definition of the database for historical access of the data. If this property exists, historical access is enabled, otherwise it is not enabled.
Properties of the database
object:
type
(string, enum)
type
(string, enum)Type of the history database
This element must be one of the following enum values:
influx
Default: "influx"
Example: "influx"
host
(string)
host
(string)Database Host
Example: "10.20.30.40"
port
(integer)
port
(integer)Port of the database server
Default: 8086
Example: 8086
name
(string)
name
(string)Database Name
Example: "opcuaHistory"
retention
(integer)
retention
(integer)Data older than the specified number of days will be automatically discarded
Example: 356
Last updated