LogoLogo
Contact Uscybus.io
Connectware 1.8.0
Connectware 1.8.0
  • Getting Started
    • Introduction
    • Installing Connectware
      • System Requirements
      • Acquiring your License Key
      • Installing Connectware on Docker
      • Installing Connectware on Kubernetes
    • Connectware Admin UI
    • Basic Components of Connectware
    • Connecting your First Machine
      • Your First Service Commissioning File
  • Documentation
    • Services
      • Service Commissioning Files
        • Structure of Service Commissioning Files
          • description
          • metadata
          • parameters
          • definitions
          • resources
            • Cybus::Connection
            • Cybus::Endpoint
            • Cybus:Mapping
            • Cybus::Container
              • Docker problem with network changes
            • Cybus::Link
            • Cybus::IngressRoute
            • Cybus::User
            • Cybus::Role
            • Cybus::Volume
            • Cybus::File
            • Cybus::Server
            • Cybus::Node
        • Sample Service Commissioning Files
          • Modbus
            • “Bearbeitungszentrum BAZ” - Single File
            • “Bearbeitungszentrum BAZ” - Multiple Files
            • “Bearbeitungszentrum BAZ” - Single File and Custom Topics
            • “Bearbeitungszentrum BAZ” - Agent Mode
          • Machine Condition Monitoring : OPC UA + InfluxDB + Grafana Dashboard
            • “Machine Condition Monitoring Example” - Single File
          • Machine Utilization Example (Multi file service composition) : Modbus TCP + InfluxDB + Grafana + MSS
            • “Machine Utilization Example” - Machine Connectivity
            • “Machine Utilization Example” - Dashboards with role based access permission
            • “Machine Utilization Example” - Push data to MSSQL Database
      • Services View
      • Setting Up and Configuring Services
        • Installing Services
        • Enabling Services
        • Updating Services
        • Disabling Services
        • Deleting Services
      • Service Details View
      • ServiceID
      • Inter-Service Referencing
      • Deviation
      • Service Logs
        • Logs of Individual Services
        • Logs of All Services
      • Rule Engine
        • Data Processing Rules
        • Rule Sandbox
      • API Definition
    • Resources
      • Servers
      • Containers
      • Volumes
      • Connections
      • Endpoints
      • Mappings
      • Nodes
      • API Definition
    • User Management
      • Users and Roles View
      • Users
      • Roles
      • Permissions
      • Password Policy Rules
      • Default Admin User
      • MQTT Users
      • Adding a MQTT Publish Prefix for Users
      • Multi-Factor Authentication
      • Long lived JSON Web Tokens
      • Access Permissions for Admin-UI
        • UI Access
        • Minimum Access Role Pages
      • API Definition
    • Client Registry
      • Implicit Flow
      • Explicit Flow
      • Granting Access
      • API Definition
    • Certificates
    • Monitoring
      • Data Explorer
      • Live Data
    • Workbench
      • Flows in Git Repositories
    • System Status
      • Info
      • Metrics
      • Status
      • Retrieving More System Information
      • System Health
      • API Definition
    • Backup and Restore
      • Volumes
      • User Database
    • Configuration
      • Environment Variables
      • LDAP Configuration
      • MFA Configuration
    • Agents
      • Agents View
      • Installing Agents
        • Installing Agents via Docker
        • Installing Agents via Docker Compose
        • Installing Agents via Kubernetes
        • Using Mutual TLS for Agents
      • Registering Agents in Connectware
      • Using Agents
      • Monitoring Agents
      • Troubleshooting Agents
    • Industry Protocol Details
      • ADS
        • AdsConnection
        • AdsEndpoint
      • BACnet
        • BacnetConnection
        • BacnetEndpoint
      • EtherNet/IP
        • EthernetIpConnection
        • EthernetIpEndpoint
      • Focas
        • FocasConnection
        • FocasEndpoint
      • Generic VRPC
        • GenericVrpcConnection
        • GenericVrpcEndpoint
      • Hottinger Baldwin Messtechnik (HBM)
        • HbmdaqConnection
        • HbmdaqEndpoint
      • Heidenhain DNC
        • HeidenhainConnection
        • HeidenhainEndpoint
      • HTTP/REST
        • HttpConnection
        • HttpEndpoint
      • HTTP Server
        • HttpServer
        • HttpNode
      • InfluxDB
        • InfluxdbConnection
        • InfluxdbEndpoint
      • Kafka
        • KafkaConnection
        • KafkaEndpoint
      • Modbus/TCP
        • ModbusConnection
        • ModbusEndpoint
      • MQTT
        • MqttConnection
        • MqttEndpoint
      • MSSQL
        • MssqlConnection
        • MssqlEndpoint
      • OPC DA
        • OpcdaConnection
        • OpcdaEndpoint
      • OPC UA
        • OPC UA Client
          • OpcuaConnection
          • OpcuaEndpoint
        • OPC UA Server
          • OpcuaServer
          • OpcuaNode
        • OPC UA Object Types
        • OPC UA Server References
          • OpcuaReferenceNode
          • OpcuaObjectNode
      • Siemens SIMATIC S7
        • S7Connection
        • S7Endpoint
      • Shdr
        • ShdrConnection
        • ShdrEndpoint
      • Sinumerik
        • SinumerikConnection
        • SinumerikEndpoint
      • Sopas
        • SopasConnection
        • SopasEndpoint
      • SQL
        • SqlConnection
        • SqlEndpoint
      • Werma WIN Ethernet
        • WermaConnection
        • WermaEndpoint
      • Systemstate
        • SystemstateConnection
        • SystemstateEndpoint
      • API Definition
    • Connectware Licensing
    • Changelog
      • General changes from 0.x to 1.0
        • Upgrading from 0.x to 1.0
    • Upgrade Guide
      • Upgrading from 1.x to 1.7.0
      • Upgrading from 1.x to 1.5.0
Powered by GitBook
LogoLogo

Cybus

  • Terms and Condition
  • Imprint
  • Data Privacy

© Copyright 2025, Cybus GmbH

On this page
  • host (string, required)
  • port (integer, required)
  • resourcePath (string)
  • username (string)
  • password (string)
  • timeout (integer)
  • certificateFile (string)
  • privateKeyFile (string)
  • checkHostReachable (boolean)
  • maxMonitoredItemsPerCall (integer)
  • options (object)

Was this helpful?

  1. Documentation
  2. Industry Protocol Details
  3. OPC UA
  4. OPC UA Client

OpcuaConnection

host (string, required)

Hostname or IP of the OPC UA device

Example: "192.168.2.60"

port (integer, required)

Port of the OPC UA device

Default: 4840

Example: 4840

resourcePath (string)

Resource Path of the OPC UA server. Please note that this should be set to a valid value as some OPC-UA servers experience issues when connecting without one

Default: ""

Example: ""

username (string)

Username for OPC UA server

Example: "user"

password (string)

Password for OPC UA server

Example: "user"

timeout (integer)

Timeout, in milliseconds

Default: 1000

Examples: 1000, 2000

certificateFile (string)

Absolute path to the client certificate file

Example: "/connectware_certs/cybus_client.crt"

privateKeyFile (string)

Absolute path to the client private key file

Example: "/connectware_certs/cybus_client.key"

checkHostReachable (boolean)

Checks if a low level TCP connection can be made to the configured host and port

Default: false

maxMonitoredItemsPerCall (integer)

If non-zero, multiple monitoredItems (i.e. multiple endpoints/nodes) will be registered in groups of maximum size of this given number. This is a server configuration property that can be queried on the server at nodeId: ns=0;i=11714. If this value is zero, no maximum value is assumed and all endpoints will be registered in one call.

Default: 0

options (object)

Properties of the options object:

defaultSecureTokenLifetime (integer)

Lifetime of the secure token. Specified in milliseconds.

Default: 3600000

requestedSessionTimeout (integer)

OPC UA sessions may survive TCP connection breaks and are only deleted if no message from a client is received within the timeout period. Specified in milliseconds.

Default: 3600000

transportTimeout (integer)

Secure channel creating timeout, used before connecting or reconnecting to an OPC UA host. Has an impact on when a deviation is thrown as reconnect is first trying to connect to the host.

Default: 60000

endpointMustExist (boolean)

Specifies if the connection is strictly meant for the given endpoint. If false and the endpoint doesn’t exist, a reasonable default endpoint is automatically chosen.

Default: false

messageSecurityMode (string, enum)

This element must be one of the following enum values:

  • None

  • Sign

  • SignAndEncrypt

Default: "None"

securityPolicy (string, enum)

This element must be one of the following enum values:

  • Aes128_Sha256_RsaOaep

  • Basic128

  • Basic128Rsa15

  • Basic192

  • Basic192Rsa15

  • Basic256

  • Basic256Rsa15

  • Basic256Sha256

  • None

  • PubSub_Aes128_CTR

  • PubSub_Aes256_CTR

Default: "None"

watchInterval (integer)

For observing connection breaks, a connection watchdog runs regularly. Short intervals guarantee short notice on break but lead to higher load. Specified in milliseconds

Default: 30000

connectionStrategy (object)

If a connection attempt fails, retries will be performed with increasing delay (waiting time) in between. The following parameters control how these delays behave.

Properties of the connectionStrategy object:

maxRetry (integer)

Maximum number of connection retries in case of failure.

Default: 1000000000

initialDelay (integer)

Delay (waiting time) of the first connection retry (in milliseconds). For subsequent retries, the delay will be increased by a factor of 2, and also by a potential random increase according to the parameter randomisationFactor.

Default: 1000

maxDelay (integer)

Maximum delay (waiting time) to wait until the next retry (in milliseconds). The delay (waiting time) for any subsequent connection retry will not be larger than this value. Must be strictly greater than initialDelay.

Default: 30000

randomisationFactor (number)

This parameter controls added randomisation to the retry attempts. Must be a number between 0 and 1. If set to 0, retries will be performed with exponentially growing delay until maxDelay. If set to 1, a maximum noise will be added to the retry delays.

Default: 0

Additional restrictions:

  • Maximum: 1

PreviousOPC UA ClientNextOpcuaEndpoint

Last updated 6 months ago

Was this helpful?