LogoLogo
Contact Uscybus.io
Connectware 1.8.0
Connectware 1.8.0
  • Getting Started
    • Introduction
    • Installing Connectware
      • System Requirements
      • Acquiring your License Key
      • Installing Connectware on Docker
      • Installing Connectware on Kubernetes
    • Connectware Admin UI
    • Basic Components of Connectware
    • Connecting your First Machine
      • Your First Service Commissioning File
  • Documentation
    • Services
      • Service Commissioning Files
        • Structure of Service Commissioning Files
          • description
          • metadata
          • parameters
          • definitions
          • resources
            • Cybus::Connection
            • Cybus::Endpoint
            • Cybus:Mapping
            • Cybus::Container
              • Docker problem with network changes
            • Cybus::Link
            • Cybus::IngressRoute
            • Cybus::User
            • Cybus::Role
            • Cybus::Volume
            • Cybus::File
            • Cybus::Server
            • Cybus::Node
        • Sample Service Commissioning Files
          • Modbus
            • “Bearbeitungszentrum BAZ” - Single File
            • “Bearbeitungszentrum BAZ” - Multiple Files
            • “Bearbeitungszentrum BAZ” - Single File and Custom Topics
            • “Bearbeitungszentrum BAZ” - Agent Mode
          • Machine Condition Monitoring : OPC UA + InfluxDB + Grafana Dashboard
            • “Machine Condition Monitoring Example” - Single File
          • Machine Utilization Example (Multi file service composition) : Modbus TCP + InfluxDB + Grafana + MSS
            • “Machine Utilization Example” - Machine Connectivity
            • “Machine Utilization Example” - Dashboards with role based access permission
            • “Machine Utilization Example” - Push data to MSSQL Database
      • Services View
      • Setting Up and Configuring Services
        • Installing Services
        • Enabling Services
        • Updating Services
        • Disabling Services
        • Deleting Services
      • Service Details View
      • ServiceID
      • Inter-Service Referencing
      • Deviation
      • Service Logs
        • Logs of Individual Services
        • Logs of All Services
      • Rule Engine
        • Data Processing Rules
        • Rule Sandbox
      • API Definition
    • Resources
      • Servers
      • Containers
      • Volumes
      • Connections
      • Endpoints
      • Mappings
      • Nodes
      • API Definition
    • User Management
      • Users and Roles View
      • Users
      • Roles
      • Permissions
      • Password Policy Rules
      • Default Admin User
      • MQTT Users
      • Adding a MQTT Publish Prefix for Users
      • Multi-Factor Authentication
      • Long lived JSON Web Tokens
      • Access Permissions for Admin-UI
        • UI Access
        • Minimum Access Role Pages
      • API Definition
    • Client Registry
      • Implicit Flow
      • Explicit Flow
      • Granting Access
      • API Definition
    • Certificates
    • Monitoring
      • Data Explorer
      • Live Data
    • Workbench
      • Flows in Git Repositories
    • System Status
      • Info
      • Metrics
      • Status
      • Retrieving More System Information
      • System Health
      • API Definition
    • Backup and Restore
      • Volumes
      • User Database
    • Configuration
      • Environment Variables
      • LDAP Configuration
      • MFA Configuration
    • Agents
      • Agents View
      • Installing Agents
        • Installing Agents via Docker
        • Installing Agents via Docker Compose
        • Installing Agents via Kubernetes
        • Using Mutual TLS for Agents
      • Registering Agents in Connectware
      • Using Agents
      • Monitoring Agents
      • Troubleshooting Agents
    • Industry Protocol Details
      • ADS
        • AdsConnection
        • AdsEndpoint
      • BACnet
        • BacnetConnection
        • BacnetEndpoint
      • EtherNet/IP
        • EthernetIpConnection
        • EthernetIpEndpoint
      • Focas
        • FocasConnection
        • FocasEndpoint
      • Generic VRPC
        • GenericVrpcConnection
        • GenericVrpcEndpoint
      • Hottinger Baldwin Messtechnik (HBM)
        • HbmdaqConnection
        • HbmdaqEndpoint
      • Heidenhain DNC
        • HeidenhainConnection
        • HeidenhainEndpoint
      • HTTP/REST
        • HttpConnection
        • HttpEndpoint
      • HTTP Server
        • HttpServer
        • HttpNode
      • InfluxDB
        • InfluxdbConnection
        • InfluxdbEndpoint
      • Kafka
        • KafkaConnection
        • KafkaEndpoint
      • Modbus/TCP
        • ModbusConnection
        • ModbusEndpoint
      • MQTT
        • MqttConnection
        • MqttEndpoint
      • MSSQL
        • MssqlConnection
        • MssqlEndpoint
      • OPC DA
        • OpcdaConnection
        • OpcdaEndpoint
      • OPC UA
        • OPC UA Client
          • OpcuaConnection
          • OpcuaEndpoint
        • OPC UA Server
          • OpcuaServer
          • OpcuaNode
        • OPC UA Object Types
        • OPC UA Server References
          • OpcuaReferenceNode
          • OpcuaObjectNode
      • Siemens SIMATIC S7
        • S7Connection
        • S7Endpoint
      • Shdr
        • ShdrConnection
        • ShdrEndpoint
      • Sinumerik
        • SinumerikConnection
        • SinumerikEndpoint
      • Sopas
        • SopasConnection
        • SopasEndpoint
      • SQL
        • SqlConnection
        • SqlEndpoint
      • Werma WIN Ethernet
        • WermaConnection
        • WermaEndpoint
      • Systemstate
        • SystemstateConnection
        • SystemstateEndpoint
      • API Definition
    • Connectware Licensing
    • Changelog
      • General changes from 0.x to 1.0
        • Upgrading from 0.x to 1.0
    • Upgrade Guide
      • Upgrading from 1.x to 1.7.0
      • Upgrading from 1.x to 1.5.0
Powered by GitBook
LogoLogo

Cybus

  • Terms and Condition
  • Imprint
  • Data Privacy

© Copyright 2025, Cybus GmbH

On this page

Was this helpful?

  1. Documentation
  2. Services

ServiceID

PreviousService Details ViewNextInter-Service Referencing

Last updated 6 months ago

Was this helpful?

A acts as a template for creating a concrete service. It is the template only, much like in a programming language the class serves as a template for concrete object instantiations. When a service, the concrete service can be configured by choosing different values for the parameters of the commissioning file. In this configuration step, the serviceId is chosen as a unique identifier for this concrete service.

The serviceId may consist of ascii characters (lower and upper case), numbers, underscore, and period (decimal point), identical to how Docker container names may be chosen (regular expression pattern: [a-zA-Z0-9][a-zA-Z0-9_.]*). If no serviceId is specified explicitly, an auto-generated one is used, and also proposed as default when installing a service. The auto-generated serviceId is taken from the property with all non-allowed characters removed. For backward-compatibility reasons, the auto-generated serviceId in 1.0.x changes all characters to lowercase and also removes all punctuation, including underscore and period.

Due to different parameter choices, the concrete services may be very different once enabled, even when the same commissioning file was used. Hence, the serviceId is used as the unique identifier for each enabled service.

The serviceId is also important when referencing resources in other services for .

The length of the serviceId is generally not restricted, except if there are any or resources in the given service commissioning file. For any of these resources, the resulting resource name from serviceId and resourceId together must be not longer than 63 characters, which is a limitation from the Docker container hostname property. If any of these resources exist in the file, the serviceId will be checked to be not longer than what is possible while still fulfilling the resource name restriction on the container resources. For example, if there is a Cybus::Container resource with a 10 character long resourceId, the serviceId must be at most 52 characters long (63, minus 10, minus 1 hyphen character). This check will be performed upon installation of the service.

Footnotes

[]

There is one exception from the Docker analogy: The hyphen character - (also called minus) is intentionally not allowed for identifiers within the Connectware, because it is used internally as the separator character between service ID and resource ID e.g. for Docker container resources.

commissioning file
installing
[1]
inter-service referencing
Cybus::Container
Cybus::Volume
1
metadata name