LogoLogo
Contact Uscybus.io
Connectware 1.11.0
Connectware 1.11.0
  • Getting Started
    • Introduction
    • System Requirements
    • Connectware Admin UI
    • Basic Components of Connectware
    • Connecting your First Machine
      • Your First Service Commissioning File
  • Documentation
    • Installation and Upgrades
      • Installing Connectware
        • Installing Connectware (Kubernetes)
        • Installing Connectware (Docker)
      • Upgrading Connectware
        • Upgrading Connectware (Kubernetes)
          • Version-Specific Upgrades (Kubernetes)
        • Upgrading Connectware (Docker)
          • Version-Specific Upgrades (Docker)
      • Uninstalling Connectware
        • Uninstalling Connectware (Kubernetes)
        • Uninstalling Connectware (Docker)
      • Licensing
      • Restarting Connectware
    • User Management
      • Users and Roles View
      • Users
      • Roles
      • Permissions
      • Password Policy Rules
      • Default Admin User
      • MQTT Users
      • Adding a MQTT Publish Prefix for Users
      • Multi-Factor Authentication
      • Single Sign-On (SS0)
        • Single Sign-On with Microsoft Entra ID
        • Single Sign-On with LDAP
      • JSON Web Tokens
      • Access Permissions for Admin-UI
        • UI Access
        • Minimum Access Role Pages
    • Services
      • Service Overview
      • Service Resources View
        • Service Links View
        • Servers View
        • Containers View
        • Volumes View
        • Connections View
        • Endpoints View
        • Mappings View
      • Service Details View
      • Service Commissioning Files
        • Version
        • Description
        • Metadata
        • Parameters
        • Definitions
        • Resources
          • Cybus::Connection
          • Cybus::Container
            • Docker Problem with Network Changes
          • Cybus::Endpoint
          • Cybus::File
          • Cybus::IngressRoute
          • Cybus::Link
          • Cybus:Mapping
          • Cybus::Node
          • Cybus::Role
          • Cybus::Server
          • Cybus::User
          • Cybus::Volume
      • Setting Up and Configuring Services
        • Installing Services
        • Enabling Services
        • Updating Services
        • Disabling Services
        • Deleting Services
      • FlowSync
        • Example 1 - Node with Transaction Mode (HTTP)
        • Example 2 - Node Responds (HTTP)
        • Example 3 - Node with Error (HTTP)
        • Example 4 - Node with Timeout Error Code and Error Message (HTTP)
        • Example 5 - Full Transactional Data Flow (HTTP)
        • Example 6 - Full Transactional Data Flow (OPC UA)
      • ServiceID
      • Inter-Service Referencing
      • Deviations
      • Service Logs
        • Logs of Individual Services
        • Logs of All Services
      • Rule Engine
        • Data Processing Rules
        • Rule Sandbox
      • Shared Subscriptions
        • Setting Up Shared Subscriptions
    • Agents
      • Agents View
      • Installing Agents
        • Installing Agents via Docker
        • Installing Agents via Docker Compose
        • Installing Agents via Kubernetes
        • Using Mutual TLS for Agents
      • Registering Agents in Connectware
      • Using Agents
      • Monitoring Agents
      • Agents in Kubernetes
        • Adding Agents Inside your Connectware Installation
        • Remote Agents with the connectware-agent Helm Chart
        • Kubernetes Cluster Requirements for the connectware-agent Helm Chart
        • Installing Connectware Agents using the connectware-agent Helm Chart
        • Installing Connectware Agents without a License Key Using the connectware-agent Helm Chart
        • Upgrading the connectware-agent Helm Chart
        • Uninstalling Connectware agents with the connectware-agent Helm chart
        • Configuration Principles for the connectware-agent Helm Chart
        • Configuring Agents with the connectware-agent Helm Chart
          • Configuring Target Connectware for the connectware-agent Helm Chart
          • Configuring Agent Persistence for the connectware-agent Helm Chart
          • Configuring Compute Resources for the connectware-agent Helm Chart
          • Using a Custom Image Registry for the connectware-agent Helm Chart
          • Configuring Image Pull Policy for the connectware-agent Helm Chart
          • Using Mutual Transport Layer Security (mTLS) for agents with the connectware-agent Helm chart
          • Configuring image name and version for the connectware-agent Helm chart
          • Configuring Environment Variables for the connectware-agent Helm Chart
          • Configuring Labels and Annotations for the connectware-agent Helm Chart
          • Configuring podAntiAffinity for the connectware-agent Helm Chart
          • Assigning Agents to Kubernetes Nodes for the connectware-agent Helm Chart
          • Configuring Security Context for the connectware-agent Helm Chart
          • Controlling the Name of Kubernetes Objects for the connectware-agent Helm Chart
      • Troubleshooting Agents
    • Client Registry
      • Implicit Flow
      • Explicit Flow
      • Granting Access
    • Certificates
      • Certificates View
      • Adding Certificates
      • Removing Certificates
    • Monitoring
      • Data Explorer
      • Live Data
    • Node-RED Workbench
    • System Status
      • Info
      • Metrics
      • Status
      • Retrieving More System Information
      • System Health
    • Backup and Restore
      • Volumes
      • User Database
    • CybusMQ
      • Configuring CybusMQ
    • Connectware on Kubernetes
      • Connectware Helm Chart
      • Resizing Broker Volumes in Kubernetes
      • Configuring Core Services
      • LDAP Authentication
        • Configuring LDAP Authentication
        • Enabling TLS for LDAP Authentication
        • Manual Kubernetes Secret for LDAP Authentication Bind User
        • Customizing the Search Filter for LDAP Authentication
        • Customizing the User RDN for LDAP Authentication
      • Troubleshooting Connectware on Kubernetes
    • Environment Variables
    • Industry Protocol Details
      • ADS
        • ADS Connection Properties
        • ADS Endpoint Properties
      • BACnet
        • BACnet Connection Properties
        • BACnet Endpoint Properties
      • Custom Connectors
        • Developing Custom Connectors
        • Deploying Custom Connectors
        • Using Custom Connectors
      • EtherNet/IP
        • EtherNet/Ip Connection Properties
        • EtherNet/Ip Endpoint Properties
      • FOCAS
        • FOCAS Connection Properties
        • FOCAS Endpoint Properties
      • Hottinger Baldwin Messtechnik (HBM)
        • HBM Connection Properties
        • HBM Endpoint Properties
      • Heidenhain DNC
        • Heidenhain DNC Connection Properties
        • Heidenhain DNC Endpoint Properties
      • HTTP/REST
        • HTTP/REST Connection Properties
        • HTTP/REST Endpoint Properties
      • HTTP Server/Node
        • HTTP Server Properties
        • HTTP Node Properties
      • InfluxDB
        • InfluxDB Connection Properties
        • InfluxDB Endpoint Properties
      • Kafka
        • Kafka Connection Properties
        • Kafka Endpoint Properties
      • Modbus/TCP
        • Modbus/TCP Connection Properties
        • Modbus/TCP Endpoint Properties
      • MQTT
        • MQTT Connection Properties
        • MQTT Endpoint Properties
      • MSSQL
        • Mssql Connection Properties
        • Mssql Endpoint Properties
      • OPC DA
        • OPC DA Connection Properties
        • OPC DA Endpoint Properties
      • OPC UA
        • OPC UA Client
          • OPC UA Client Connection Properties
          • OPC UA Client Endpoint Properties
        • OPC UA Server
          • OPC UA Server Properties
          • OPC UA Node Properties
        • OPC UA Object Types
        • OPC UA Server References
          • OPC UA Reference Node
          • OPC UA Object Node
      • Siemens SIMATIC S7
        • Siemens S7 Connection Properties
        • Siemens S7 Endpoint Properties
      • Shdr
        • Shdr Connection Properties
        • Shdr Endpoint Properties
      • SINUMERIK
        • SINUMERIK Connection Properties
        • SINUMERIK Endpoint Properties
      • SOPAS
        • SOPAS Connection Properties
        • SOPAS Endpoint Properties
      • SQL
        • SQL Connection Properties
        • SQL Endpoint Properties
      • Werma WIN Ethernet
        • Werma WIN Ethernet Connection Properties
        • Werma WIN Ethernet Endpoint Properties
      • Systemstate
        • Systemstate Endpoint Properties
    • API Reference
      • User Management (API)
      • Client Registry (API)
      • Services (API)
      • Resources (API)
      • System Status (API)
      • Resource Status Tracking (HTTP API)
      • Industry Protocol Details (API)
    • Changelog
Powered by GitBook
LogoLogo

Cybus

  • Terms and Condition
  • Imprint
  • Data Privacy

© Copyright 2025, Cybus GmbH

On this page
  • port (integer)
  • maxSessions (integer)
  • maxConnections (integer)
  • resourcePath (string)
  • alternateHostname (string)
  • hostname (string)
  • applicationUri (string)
  • allowAnonymous (boolean)
  • certificateFile (string)
  • privateKeyFile (string)
  • securityPolicies (array)
  • nodesetFiles (array)
  • securityModes (array)
  • database (object)

Was this helpful?

  1. Documentation
  2. Industry Protocol Details
  3. OPC UA
  4. OPC UA Server

OPC UA Server Properties

port (integer)

Port of the listening socket

Default: 4841

Example: 4841

maxSessions (integer)

Max Sessions allowed by user

Default: 20

Example: 1000

maxConnections (integer)

Max Connections allowed for a single endpoint to prevent DDoS attacks

Default: 20

Example: 1000

resourcePath (string)

Resource Path of the OPC Server. This must be added to the OPC UA connection URN of the client

Default: "/UA/CybusOpcuaServer"

Examples: "/UA/CybusOpcuaServer", "/My/IndividualName"

alternateHostname (string)

This setting is deprecated, has been renamed into 'hostname', and will be removed in a future release

Examples: "10.20.30.40", "my.connectware-host.company.com"

hostname (string)

The hostname by which the Connectware with the OPC UA server will be reachable on the system. This can be either an IP address or a DNS name.

Examples: "10.20.30.40", "my.connectware-host.company.com"

applicationUri (string)

The application URI is used to define the namespace name of the Connectware defined NodeIds

Default: "urn:cybus:opcua:server:1"

Example: "urn:cybus:opcua:server:1"

allowAnonymous (boolean)

If true, usage of anonymous access token is allowed. In that case, OPC UA clients are allowed to connect without any authentication. Note: This is a high security risk and must not be used in production deployments.

Default: false

Example: true

certificateFile (string)

Absolute path to the server certificate file

Default: "/connectware_certs/cybus_server.crt"

Example: "/connectware_certs/cybus_server.crt"

privateKeyFile (string)

Absolute path to the server private key file

Default: "/connectware_certs/cybus_server.key"

Example: "/connectware_certs/cybus_server.key"

securityPolicies (array)

Defines the list of OPC UA securityPolicies that will be available on the server. Note: The policy "None" is a high security risk and must not be used in production deployments.

The object is an array with all elements of the type string.

Each element of the array must be one of the following enum values:

  • Basic256Sha256

  • None

Default:

[
  "Basic256Sha256"
]

Example: "[\"Basic256Sha256\", \"None\"]"

nodesetFiles (array)

Predefined Nodeset files to load on startup

The object is an array with all elements of the type string.

Each element of the array must be one of the following enum values:

  • standard

  • di

  • ia

  • machinery

  • machineTool

  • packML

  • robotics

  • Opc.Ua.PlasticsRubber.GeneralTypes.NodeSet2.xml

  • Opc.Ua.PlasticsRubber.IMM2MES.NodeSet2.xml

  • Opc.Ua.PLCopen.NodeSet2.xml

securityModes (array)

Defines the list of OPC UA security modes which an OPC client can use to establish a connection to the Cybus OPC UA server

The object is an array with all elements of the type string.

Each element of the array must be one of the following enum values:

  • Invalid

  • None

  • Sign

  • SignAndEncrypt

Default:

[
  "SignAndEncrypt"
]

Example: "[\"None\", \"SignAndEncrypt\"]"

database (object)

Definition of the database for historical access of the data. If this property exists, historical access is enabled, otherwise it is not enabled.

Properties of the database object:

type (string, enum)

Type of the history database

This element must be one of the following enum values:

  • influx

Default: "influx"

Example: "influx"

host (string)

Database Host

Example: "10.20.30.40"

port (integer)

Port of the database server

Default: 8086

Example: 8086

name (string)

Database Name

Example: "opcuaHistory"

retention (integer)

Data older than the specified number of days will be automatically discarded

Example: 356

PreviousOPC UA ServerNextOPC UA Node Properties

Last updated 2 months ago

Was this helpful?