SopasEndpoint

type (string, enum, required)

The type of the identifier. It can be one of the following: event, method or variable.

This element must be one of the following enum values:

  • event

  • method

  • variable

name (string, required)

The name of the method to call. For example MIStartIn.

index (string)

The index number of the method to call.

accessMode (integer)

The access mode (user level) when writing to a variable in the device. The default access mode 0 (zero) is always active. Higher access modes such as 1 (Operator), 2 (Maintenance), 3 (Authorized Client), or 4 (Service) all require some password, which should be listed in the manufacturer's documentation. (The numbers 5 through 7 are internal values of the manufacturer.)

Default: 0

Additional restrictions:

  • Maximum: 7

password (string)

Only needed with an increased access mode (user level) parameter, when writing to a variable in the device.

Last updated